7 results (0.002 seconds)

CVSS: 9.4EPSS: 0%CPEs: 9EXPL: 0

A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. • https://cert-portal.siemens.com/productcert/html/ssa-629254.html • CWE-250: Execution with Unnecessary Privileges •

CVSS: 7.1EPSS: 0%CPEs: 4EXPL: 0

A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. Se ha identificado una vulnerabilidad en: OpenPCS 7 V9.1 (todas las versiones), SIMATIC BATCH V9.1 (todas las versiones), SIMATIC PCS 7 V9.1 (todas las versiones), SIMATIC Route Control V9.1 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones), SIMATIC WinCC Runtime Professional V19 (todas las versiones), SIMATIC WinCC V7.4 (todas las versiones), SIMATIC WinCC V7.5 (todas las versiones &lt; V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (Todas las versiones A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. • https://cert-portal.siemens.com/productcert/html/ssa-753746.html • CWE-476: NULL Pointer Dereference •

CVSS: 7.1EPSS: 0%CPEs: 4EXPL: 0

A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. Se ha identificado una vulnerabilidad en: OpenPCS 7 V9.1 (todas las versiones), SIMATIC BATCH V9.1 (todas las versiones), SIMATIC PCS 7 V9.1 (todas las versiones), SIMATIC Route Control V9.1 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones), SIMATIC WinCC Runtime Professional V19 (todas las versiones), SIMATIC WinCC V7.4 (todas las versiones), SIMATIC WinCC V7.5 (todas las versiones &lt; V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (Todas las versiones A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. • https://cert-portal.siemens.com/productcert/html/ssa-753746.html • CWE-476: NULL Pointer Dereference •

CVSS: 7.7EPSS: 0%CPEs: 39EXPL: 0

A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. Se ha identificado una vulnerabilidad en OpenPCS 7 V8.2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a la versión a la versión V9.0 Upd4), OpenPCS 7 V9.1 (Todas las versiones), SIMATIC BATCH V8.2 (Todas las versiones), SIMATIC BATCH V9.0 (Todas las versiones), SIMATIC BATCH V9. 1 (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versión a la versión V16 Update 6), SIMATIC NET PC Software V17 (Todas las versiones anteriores a la versión a la versión V17 SP1), SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9. 0 (Todas las versiones anteriores a la versión a la versión V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a la versión a la versión V9.1 SP1), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones), SIMATIC Route Control V9. 1 (Todas las versiones), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a la versión a la versión V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a la versión a la versión V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a la versión a la versión V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a la versión V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versión V7.5 SP2 Update 5). Al descargar archivos, los sistemas afectados no neutralizan correctamente los elementos especiales dentro del nombre de la ruta. • https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 7.5EPSS: 0%CPEs: 44EXPL: 0

A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction. Se ha identificado una vulnerabilidad en OpenPCS 7 V8.1 (Todas las versiones), OpenPCS 7 V8.2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a V9.0 Upd3), SIMATIC BATCH V8.1 (Todas las versiones), SIMATIC BATCH V8.2 (Todas las versiones), SIMATIC BATCH V9.0 (Todas las versiones anteriores a V9. 0 SP1 Upd5), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a V16 Update 1), SIMATIC PCS 7 V8.1 (Todas las versiones), SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9. 0 SP3), SIMATIC Route Control V8.1 (Todas las versiones), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones anteriores a V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) V14 (Todas las versiones anteriores a V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15. 1 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 1), SIMATIC WinCC V7.3 (Todas las versiones), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP1 Update 1). A través de mensajes especialmente diseñados, cuando la comunicación cifrada está habilitada, un atacante con acceso a la red podría utilizar la vulnerabilidad para comprometer la disponibilidad del sistema causando una condición de denegación de servicio. La explotación exitosa no requiere privilegios del sistema ni interacción del usuario • https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf • CWE-131: Incorrect Calculation of Buffer Size •