CVSS: 6.9EPSS: 0%CPEs: 82EXPL: 0

The web server of affected devices do not properly authenticate user request to the '/ClientArea/RuntimeInfoData.mwsl' endpoint. This could allow an unauthenticated remote attacker to gain knowledge about current actual and configured maximum cycle times as well as about configured maximum communication load. • https://cert-portal.siemens.com/productcert/html/ssa-054046.html • CWE-288: Authentication Bypass Using an Alternate Path or Channel •

CVSS: 5.1EPSS: 0%CPEs: 141EXPL: 0

The web server of affected devices does not properly validate input that is used for a user redirection. This could allow an attacker to make the server redirect the legitimate user to an attacker-chosen URL. For a successful exploit, the legitimate user must actively click on an attacker-crafted link. • https://cert-portal.siemens.com/productcert/html/ssa-876787.html • CWE-601: URL Redirection to Untrusted Site ('Open Redirect') •

CVSS: 7.5EPSS: 0%CPEs: 152EXPL: 0

Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial of service condition. A restart is needed to restore normal operations. Los dispositivos afectados manejan incorrectamente paquetes especialmente manipulados enviados al puerto 102/tcp. Esto podría permitir que un atacante cree una condición de denegación de servicio. Es necesario reiniciar para restaurar las operaciones normales. • https://cert-portal.siemens.com/productcert/html/ssa-280603.html https://cert-portal.siemens.com/productcert/html/ssa-592380.html https://cert-portal.siemens.com/productcert/pdf/ssa-280603.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-592380.pdf • CWE-416: Use After Free •

CVSS: 7.5EPSS: 0%CPEs: 158EXPL: 0

The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Las implementaciones de OPC UA (ANSI C y C++) en los productos afectados contienen una vulnerabilidad de desbordamiento de enteros que podría provocar que la aplicación se ejecute en un bucle infinito durante la validación del certificado. Esto podría permitir que un atacante remoto no autenticado cree una condición de denegación de servicio enviando un certificado especialmente manipulado. • https://cert-portal.siemens.com/productcert/html/ssa-118850.html https://cert-portal.siemens.com/productcert/html/ssa-711309.html https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf • CWE-190: Integer Overflow or Wraparound •

CVSS: 7.5EPSS: 0%CPEs: 147EXPL: 0

Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition. Se ha identificado una vulnerabilidad en Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Kits de desarrollo/evaluación para PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS), SIMATIC ET200AL, SIMATIC ET200M (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incl. variantes SIPLUS) SIPLUS), SIMATIC ET200S (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incl. variantes SIPLUS). SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, paneles exteriores SIMATIC HMI Comfort de 7" y 15" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4" a 22" (incl. variantes SIPLUS), paneles móviles SIMATIC HMI KTP, acoplador SIMATIC PN/PN (incl. variantes SIPLUS NET), driver SIMATIC PROFINET, familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-1500 (incl. variantes SIPLUS). CPUs ET200 y variantes SIPLUS), SIMATIC S7-1500 Software Controller, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS). • https://cert-portal.siemens.com/productcert/html/ssa-473245.html https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf • CWE-400: Uncontrolled Resource Consumption •