13 results (0.003 seconds)

CVSS: 8.2EPSS: 0%CPEs: 13EXPL: 0

A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V16 (All versions), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC PCS 7 V9.1 (All versions), SIMATIC PDM V9.2 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. Se ha identificado una vulnerabilidad en: S7-PCT (todas las versiones), Security Configuration Tool (SCT) (todas las versiones), SIMATIC Automation Tool (todas las versiones), SIMATIC BATCH V9.1 (todas las versiones), SIMATIC NET PC Software (todas las versiones), SIMATIC PCS 7 V9.1 (todas las versiones), SIMATIC PDM V9.2 (todas las versiones), SIMATIC Route Control V9.1 (todas las versiones), SIMATIC STEP 7 V5 (todas las versiones), SIMATIC WinCC OA V3.17 ( Todas las versiones), SIMATIC WinCC OA V3.18 (todas las versiones &lt; V3.18 P025), SIMATIC WinCC OA V3.19 (todas las versiones &lt; V3.19 P010), SIMATIC WinCC Runtime Advanced (todas las versiones), SIMATIC WinCC Runtime Professional V16 (Todas las versiones), SIMATIC WinCC Runtime Professional V17 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones), SIMATIC WinCC Runtime Professional V19 (todas las versiones), SIMATIC WinCC Unified PC Runtime (todas las versiones), SIMATIC WinCC V7.4 (Todas las versiones), SIMATIC WinCC V7.5 (Todas las versiones), SIMATIC WinCC V8.0 (Todas las versiones), SINAMICS Startdrive (Todas las versiones &lt; V19 SP1), SINUMERIK ONE virtual (Todas las versiones &lt; V6.23), Programación de PLC SINUMERIK Herramienta (todas las versiones), TIA Portal Cloud Connector (todas las versiones &lt; V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Portal de automatización integrado (TIA Portal) V17 (todas las versiones), Portal de automatización totalmente integrado (Portal TIA) V18 (todas las versiones), Portal de automatización totalmente integrado (TIA Portal) V19 (todas las versiones A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. • https://cert-portal.siemens.com/productcert/html/ssa-962515.html https://cert-portal.siemens.com/productcert/html/ssa-784301.html • CWE-125: Out-of-bounds Read •

CVSS: 8.8EPSS: 0%CPEs: 7EXPL: 0

A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents. • https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf • CWE-477: Use of Obsolete Function •

CVSS: 6.5EPSS: 0%CPEs: 7EXPL: 1

The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference. Los stubs de pila ANSI C autogenerados por OPC (en los NodeSets) no manejan todos los casos de error. Esto puede conllevar a una desreferencia de puntero NULL • https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-45117.pdf https://www.youtube.com/watch?v=qv-RBdCaV4k • CWE-476: NULL Pointer Dereference •

CVSS: 7.7EPSS: 0%CPEs: 39EXPL: 0

A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. Se ha identificado una vulnerabilidad en OpenPCS 7 V8.2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a la versión a la versión V9.0 Upd4), OpenPCS 7 V9.1 (Todas las versiones), SIMATIC BATCH V8.2 (Todas las versiones), SIMATIC BATCH V9.0 (Todas las versiones), SIMATIC BATCH V9. 1 (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versión a la versión V16 Update 6), SIMATIC NET PC Software V17 (Todas las versiones anteriores a la versión a la versión V17 SP1), SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9. 0 (Todas las versiones anteriores a la versión a la versión V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a la versión a la versión V9.1 SP1), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones), SIMATIC Route Control V9. 1 (Todas las versiones), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a la versión a la versión V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a la versión a la versión V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a la versión a la versión V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a la versión V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versión V7.5 SP2 Update 5). Al descargar archivos, los sistemas afectados no neutralizan correctamente los elementos especiales dentro del nombre de la ruta. • https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 7.5EPSS: 0%CPEs: 12EXPL: 0

In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer. En OPC Foundation Local Discovery Server (LDS) versiones anteriores a 1.04.402.463, unos atacantes remotos pueden causar una denegación de servicio (DoS) mediante el envío de mensajes cuidadosamente diseñados que conllevan a el Acceso a una Ubicación de Memoria Después del Final de un Búfer. • https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf https://opcfoundation.org/security-bulletins • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •