20 results (0.003 seconds)

CVSS: 9.8EPSS: 0%CPEs: 8EXPL: 0

A vulnerability has been identified in SIMATIC Information Server 2022 (All versions), SIMATIC Information Server 2024 (All versions), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. • https://cert-portal.siemens.com/productcert/html/ssa-039007.html • CWE-122: Heap-based Buffer Overflow •

CVSS: 8.5EPSS: 0%CPEs: 3EXPL: 0

A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. Se ha identificado una vulnerabilidad en SIMATIC PCS neo V4.0 (todas las versiones), SIMATIC STEP 7 V16 (todas las versiones), SIMATIC STEP 7 V17 (todas las versiones), SIMATIC STEP 7 V18 (todas las versiones &lt; V18 Update 2). Las aplicaciones afectadas no restringen adecuadamente .NET BinaryFormatter al deserializar la entrada controlable por el usuario. • https://cert-portal.siemens.com/productcert/html/ssa-825651.html • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog. Se ha identificado una vulnerabilidad en: Opcenter Quality (todas las versiones), SIMATIC PCS neo (todas las versiones &lt; V4.1), SINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. • https://cert-portal.siemens.com/productcert/html/ssa-999588.html https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. Se ha identificado una vulnerabilidad en: Opcenter Quality (todas las versiones), SIMATIC PCS neo (todas las versiones &lt; V4.1), SINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). • https://cert-portal.siemens.com/productcert/html/ssa-999588.html https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') CWE-787: Out-of-bounds Write •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. Se ha identificado una vulnerabilidad en: Opcenter Quality (todas las versiones), SIMATIC PCS neo (todas las versiones &lt; V4.1), SINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). • https://cert-portal.siemens.com/productcert/html/ssa-999588.html https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •