10 results (0.011 seconds)

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog. Se ha identificado una vulnerabilidad en: Opcenter Quality (todas las versiones), SIMATIC PCS neo (todas las versiones &lt; V4.1), SINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. • https://cert-portal.siemens.com/productcert/html/ssa-999588.html https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. Se ha identificado una vulnerabilidad en: Opcenter Quality (todas las versiones), SIMATIC PCS neo (todas las versiones &lt; V4.1), SINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). • https://cert-portal.siemens.com/productcert/html/ssa-999588.html https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') CWE-787: Out-of-bounds Write •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. Se ha identificado una vulnerabilidad en: Opcenter Quality (todas las versiones), SIMATIC PCS neo (todas las versiones &lt; V4.1), SINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). • https://cert-portal.siemens.com/productcert/html/ssa-999588.html https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVSS: 7.1EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user. Se ha identificado una vulnerabilidad en: Opcenter Quality (todas las versiones), SIMATIC PCS neo (todas las versiones &lt; V4.1), SINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. • https://cert-portal.siemens.com/productcert/html/ssa-999588.html https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 8.8EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior. Se ha identificado una vulnerabilidad en: Opcenter Quality (todas las versiones), SIMATIC PCS neo (todas las versiones &lt; V4.1), SINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. • https://cert-portal.siemens.com/productcert/html/ssa-999588.html https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf • CWE-942: Permissive Cross-domain Policy with Untrusted Domains •