CVE-2017-14023
https://notcve.org/view.php?id=CVE-2017-14023
06 Nov 2017 — An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface. Se ha descubierto un problema de validación incorrecta de entradas en Siemens SIMATIC PCS 7 V8.1 en versiones anteriores a V8.1 SP... • http://www.securityfocus.com/bid/101680 • CWE-20: Improper Input Validation •

CVE-2017-12069
https://notcve.org/view.php?id=CVE-2017-12069
30 Aug 2017 — An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system t... • http://www.securityfocus.com/bid/100559 • CWE-611: Improper Restriction of XML External Entity Reference •

CVE-2016-7165
https://notcve.org/view.php?id=CVE-2016-7165
15 Nov 2016 — A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (... • http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html • CWE-254: 7PK - Security Features CWE-284: Improper Access Control •

CVE-2014-8551
https://notcve.org/view.php?id=CVE-2014-8551
26 Nov 2014 — The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets. El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualización 9, y 7.3 anterior a la actualización 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2, y 8.1; y TIA Portal 13 anterior a la actualización 6 permite a atacante... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf • CWE-94: Improper Control of Generation of Code ('Code Injection') •

CVE-2014-8552
https://notcve.org/view.php?id=CVE-2014-8552
26 Nov 2014 — The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets. El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualización 9, y 7.3 anterior a la actualización 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2; y 8.1; y TIA Portal 13 anterior a la actualización 6 permite a atacantes ... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVE-2014-4682 – Siemens SIMATIC WinCC Privilege Escalation
https://notcve.org/view.php?id=CVE-2014-4682
24 Jul 2014 — The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request. El servidor WebNavigator en Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, permite a atacantes remotos obtener información sensible a través de una solicitud HTTP. Siemens SIMATIC WinCC versions prior to 7.3 suffer from unauthenticated access, privilege escalation, and hard-coded encryption key vulnerabilitie... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVE-2014-4683 – Siemens SIMATIC WinCC Privilege Escalation
https://notcve.org/view.php?id=CVE-2014-4683
24 Jul 2014 — The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. El servidor WebNavigator en Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, permite a usuarios remotos autenticados ganar privilegios a través de una solicitud (1) HTTP o (2) HTTPS. Siemens SIMATIC WinCC versions prior to 7.3 suffer from unauthenticated access, privilege escalation, and hard-coded... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf • CWE-264: Permissions, Privileges, and Access Controls •

CVE-2014-4684 – Siemens SIMATIC WinCC Privilege Escalation
https://notcve.org/view.php?id=CVE-2014-4684
24 Jul 2014 — The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433. El servidor de la base de datos en Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, permite a usuarios remotos autenticados ganar privilegios a través de una solicitud en el puerto TCP 1433. Siemens SIMATIC WinCC versions prior to 7.3 suffer from unauthenticated access, privilege escalation, and hard-coded ... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf • CWE-264: Permissions, Privileges, and Access Controls •

CVE-2014-4685 – Siemens SIMATIC WinCC Privilege Escalation
https://notcve.org/view.php?id=CVE-2014-4685
24 Jul 2014 — Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, permite a usuarios locales ganar privilegios mediante el aprovechamiento de controles débiles del acceso a objetos de sistema. Siemens SIMATIC WinCC versions prior to 7.3 suffer from unauthenticated access, privilege escalation, and hard-coded encryption key vulnerabilities. • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf • CWE-264: Permissions, Privileges, and Access Controls •

CVE-2014-4686 – Siemens SIMATIC WinCC Privilege Escalation
https://notcve.org/view.php?id=CVE-2014-4686
24 Jul 2014 — The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. La aplicación de administración del proyecto en Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, tiene una clave de codificación embebida,... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf •