19 results (0.002 seconds)

CVSS: 6.9EPSS: 0%CPEs: 114EXPL: 0

11 Feb 2025 — A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALA... • https://cert-portal.siemens.com/productcert/html/ssa-769027.html • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.5EPSS: 0%CPEs: 192EXPL: 0

13 Dec 2022 — Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-1284: Improper Validation of Specified Quantity in Input •

CVSS: 7.5EPSS: 0%CPEs: 192EXPL: 0

13 Dec 2022 — Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-20: Improper Input Validation CWE-1286: Improper Validation of Syntactic Correctness of Input •

CVSS: 7.8EPSS: 0%CPEs: 192EXPL: 0

13 Dec 2022 — Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 23EXPL: 0

12 Apr 2022 — The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments. Se ha identificado una vulnerabilidad en SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200pro IM154-8 PN/DP ... • https://cert-portal.siemens.com/productcert/html/ssa-446448.html • CWE-400: Uncontrolled Resource Consumption •

CVSS: 5.9EPSS: 8%CPEs: 205EXPL: 1

25 Mar 2021 — An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS c... • https://github.com/riptl/cve-2021-3449 • CWE-476: NULL Pointer Dereference •

CVSS: 7.8EPSS: 0%CPEs: 24EXPL: 0

12 Nov 2020 — A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC TDC CPU555 (All versions), SINUMERIK 840D sl (All versions). Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port 102. A cold restart is required to recover the service. Se ha identificado una vulnerabilidad en la familia de CPUs SIMATIC S7-300 (incluidas las CPUs ET200 relacionadas y las variantes SIPLUS) (Todas las ver... • https://cert-portal.siemens.com/productcert/pdf/ssa-492828.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 6.5EPSS: 0%CPEs: 28EXPL: 0

09 Sep 2020 — A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials. ... • https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf • CWE-522: Insufficiently Protected Credentials •

CVSS: 7.5EPSS: 0%CPEs: 67EXPL: 0

14 Apr 2020 — A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), S... • https://cert-portal.siemens.com/productcert/html/ssa-593272.html • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.8EPSS: 0%CPEs: 24EXPL: 0

10 Mar 2020 — A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires ... • https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf • CWE-400: Uncontrolled Resource Consumption •