12 results (0.022 seconds)

CVSS: 7.8EPSS: 0%CPEs: 68EXPL: 0

17 Apr 2019 — A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.... • https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf • CWE-248: Uncaught Exception CWE-755: Improper Handling of Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 125EXPL: 0

17 Apr 2019 — The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. • https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

17 Apr 2019 — A vulnerability has been identified in SIMATIC S7-1500 CPU (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 CPU (All versions <= V1.8.5). Specially crafted network packets sent to port 80/tcp or 443/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/tcp or 443/tcp. Successful exploitation requires no system privileges and no user interact... • https://cert-portal.siemens.com/productcert/pdf/ssa-180635.pdf • CWE-20: Improper Input Validation •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

17 Apr 2019 — A vulnerability has been identified in SIMATIC S7-1500 CPU (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 CPU (All versions <= V1.8.5). Specially crafted network packets sent to port 80/tcp or 443/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/tcp or 443/tcp. Successful exploitation requires no system privileges and no user interact... • https://cert-portal.siemens.com/productcert/pdf/ssa-180635.pdf • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 4EXPL: 0

13 Dec 2018 — A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service ... • http://www.securityfocus.com/bid/105928 • CWE-400: Uncontrolled Resource Consumption CWE-410: Insufficient Resource Pool •

CVSS: 7.5EPSS: 0%CPEs: 6EXPL: 0

10 Oct 2018 — A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software Controller (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 incl. F (All versions >= V2.0 and < V2.5). An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with network acce... • https://cert-portal.siemens.com/productcert/pdf/ssa-347726.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 5.6EPSS: 0%CPEs: 665EXPL: 7

21 May 2018 — Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4. Los sistemas con microprocesadores que emplean la ejecución especulativa y que realizan la ejecución especulativa de lecturas de memoria antes de que se conozcan las direcciones de todas l... • https://packetstorm.news/files/id/147839 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-203: Observable Discrepancy •

CVSS: 6.5EPSS: 0%CPEs: 26EXPL: 0

20 Mar 2018 — A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All v... • https://cert-portal.siemens.com/productcert/pdf/ssa-592007.pdf • CWE-20: Improper Input Validation •

CVSS: 8.7EPSS: 0%CPEs: 76EXPL: 0

26 Dec 2017 — Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. Se ha identificado una vulnerabilidad en Development/Evaluation Kits para PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incluid... • https://cert-portal.siemens.com/productcert/html/ssa-141614.html • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.1EPSS: 0%CPEs: 181EXPL: 0

11 May 2017 — Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Los paquetes PROFINET DCP especialmente diseñados que se envían en un segmento Ethernet local (capa 2) a un producto afectado podrían causar una condi... • http://www.securityfocus.com/bid/98369 • CWE-400: Uncontrolled Resource Consumption •