5 results (0.012 seconds)

CVSS: 7.8EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). • https://cert-portal.siemens.com/productcert/pdf/ssa-113131.pdf • CWE-20: Improper Input Validation •

CVSS: 8.2EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.2.1), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). • https://cert-portal.siemens.com/productcert/pdf/ssa-113131.pdf • CWE-347: Improper Verification of Cryptographic Signature •

CVSS: 7.5EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in SIMATIC S7-400 (incl. F) CPU hardware version 4.0 and below (All versions), SIMATIC S7-400 (incl. F) CPU hardware version 5.0 (All firmware versions < V5.2), SIMATIC S7-400H CPU hardware version 4.5 and below (All versions). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. • http://www.securityfocus.com/bid/104217 https://cert-portal.siemens.com/productcert/pdf/ssa-914382.pdf https://www.siemens.com/global/en/home/products/services/cert.html#SecurityPublications • CWE-20: Improper Input Validation •

CVSS: 7.1EPSS: 0%CPEs: 181EXPL: 0

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Los paquetes PROFINET DCP especialmente diseñados que se envían en un segmento Ethernet local (capa 2) a un producto afectado podrían causar una condición de denegación de servicio de ese producto. • http://www.securityfocus.com/bid/98369 http://www.securitytracker.com/id/1038463 https://cert-portal.siemens.com/productcert/html/ssa-293562.html https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.1EPSS: 0%CPEs: 209EXPL: 0

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Los paquetes de difusión PROFINET DCP especialmente elaborados podrían causar una condición de denegación de servicio de los productos afectados en un segmento Ethernet local (capa 2). Se requiere la interacción humana para recuperar los sistemas. • http://www.securityfocus.com/bid/98369 http://www.securitytracker.com/id/1038463 https://cert-portal.siemens.com/productcert/html/ssa-284673.html https://cert-portal.siemens.com/productcert/html/ssa-293562.html https://cert-portal.siemens.com/productcert/html/ssa-546832.html https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf https://ics-cert.us- • CWE-400: Uncontrolled Resource Consumption •