CVSS: 5.5EPSS: 0%CPEs: 1EXPL: 0

12 Dec 2023 — A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) (todas las versiones < V19). Una vulnerabilidad de divulgación de información podría permitir a un ataca... • https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf • CWE-312: Cleartext Storage of Sensitive Information CWE-316: Cleartext Storage of Sensitive Information in Memory •

CVSS: 7.8EPSS: 0%CPEs: 78EXPL: 0

12 Apr 2022 — A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Port... • https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf • CWE-284: Improper Access Control •

CVSS: 7.2EPSS: 0%CPEs: 13EXPL: 0

14 Jul 2020 — A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16... • https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf • CWE-428: Unquoted Search Path or Element •

CVSS: 8.2EPSS: 0%CPEs: 20EXPL: 0

14 Jul 2020 — A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal)... • https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 5.3EPSS: 0%CPEs: 15EXPL: 0

14 Jul 2020 — A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal)... • https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf • CWE-20: Improper Input Validation •

CVSS: 7.2EPSS: 0%CPEs: 44EXPL: 0

10 Jun 2020 — A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 S... • https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf • CWE-428: Unquoted Search Path or Element •

CVSS: 5.9EPSS: 0%CPEs: 36EXPL: 0

13 Aug 2019 — A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 ... • https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •