5 results (0.005 seconds)

CVSS: 5.3EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving. Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a la versión V2017.02.3), Nucleus ReadyStart V4 (Todas las versiones anteriores a la versión V4.1.0), Nucleus Source Code (Versiones que incluyen los módulos DNS afectados), SIMOTICS CONNECT 400 (Todas las versiones anteriores a la versión V0.5.0.0), SIMOTICS CONNECT 400 (Todas las versiones posteriores o iguales a la versión V0.5.0.0 anteriores a la versión V1.0.0). El cliente DNS no aleatoriza correctamente los ID de las transacciones DNS. • https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf • CWE-330: Use of Insufficiently Random Values •

CVSS: 7.4EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition. Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2017.02.3), Nucleus ReadyStart V4 (Todas las versiones anteriores a V4.1.0), Nucleus Source Code (Versiones que incluyen los módulos DNS afectados), SIMOTICS CONNECT 400 (Todas las versiones anteriores a V0.5.0.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-788: Access of Memory Location After End of Buffer •

CVSS: 6.5EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure. Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a la versión V2017.02.3), Nucleus ReadyStart V4 (Todas las versiones anteriores a la versión V4.1.0), Nucleus Source Code (Versiones que incluyen los módulos DNS afectados), SIMOTICS CONNECT 400 (Todas las versiones anteriores a la versión V0.5.0.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf • CWE-125: Out-of-bounds Read •

CVSS: 6.5EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2017.02.3), Nucleus ReadyStart V4 (Todas las versiones anteriores a V4.1.0), Nucleus Source Code (Versiones que incluyen los módulos DNS afectados), SIMOTICS CONNECT 400 (Todas las versiones anteriores a V0.5.0.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf • CWE-125: Out-of-bounds Read CWE-170: Improper Null Termination •

CVSS: 7.1EPSS: 0%CPEs: 46EXPL: 0

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value. Se ha identificado una vulnerabilidad en APOGEE MEC/MBC/PXC (P2) (Todas las versiones anteriores a V2.8.2), APOGEE PXC Series (BACnet) (Todas las versiones anteriores a V3.5.3), APOGEE PXC Series (P2) (Todas las versiones posteriores o iguales a V2. 8.2 y anteriores a V2.8.19), Desigo PXC00-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC00-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC001-E. D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC100-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC12-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Desigo PXC128-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC200-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC22-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Desigo PXC22.1-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC36.1-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC50-E. D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC64-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXM20-E (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Nucleus NET (Todas las versiones), Nucleus RTOS (Todas las versiones), Nucleus ReadyStart para ARM, MIPS y PPC (Todas las versiones anteriores a V2017.02.2 con parche "Nucleus 2017.02. 02 Nucleus NET Patch"), Nucleus SafetyCert (Todas las versiones), Nucleus Source Code (Todas las versiones), SIMOTICS CONNECT 400 (Todas las versiones anteriores a V0.3.0.330), TALON TC Series (BACnet) (Todas las versiones anteriores a V3.5.3), VSTAR (Todas las versiones). • https://cert-portal.siemens.com/productcert/html/ssa-162506.html https://cert-portal.siemens.com/productcert/html/ssa-434032.html https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06 • CWE-20: Improper Input Validation •