12 results (0.021 seconds)

CVSS: 7.3EPSS: 0%CPEs: 17EXPL: 0

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 Update 5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 Update 5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 8), SIRIUS Safety ES V18 (All versions), SIRIUS Soft Starter ES V17 (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. • https://cert-portal.siemens.com/productcert/html/ssa-871035.html • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.0EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 Safety V16 (todas las versiones &lt; V16 Update 7), SIMATIC STEP 7 Safety V17 (todas las versiones &lt; V17 Update 7), SIMATIC STEP 7 Safety V18 (todas las versiones &lt; V18 Update 2), SIMATIC STEP 7 V16 (todas las versiones &lt; V16 Update 7), SIMATIC STEP 7 V17 (todas las versiones &lt; V17 Update 7), SIMATIC STEP 7 V18 (todas las versiones &lt; V18 Update 2), SIMATIC WinCC Unified V16 (todas las versiones &lt; V16 Update 7), SIMATIC WinCC Unified V17 (todas las versiones &lt; V17 Update 7), SIMATIC WinCC Unified V18 (todas las versiones &lt; V18 Update 2), SIMATIC WinCC V16 (todas las versiones &lt; V16.7), SIMATIC WinCC V17 (todas las versiones &lt; V17.7), SIMATIC WinCC V18 (todas las versiones &lt; V18 Update 2), SIMOCODE ES V16 (todas las versiones &lt; V16 Update 7), SIMOCODE ES V17 (todas las versiones &lt; V17 Update 7), SIMOCODE ES V18 (todas las versiones &lt; V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (Todas las versiones), SIMOTION SCOUT TIA V5.4 SP3 (Todas las versiones), SIMOTION SCOUT TIA V5.5 SP1 (Todas las versiones), SINAMICS Startdrive V16 (Todas las versiones), SINAMICS Startdrive V17 (Todas las versiones), SINAMICS Startdrive V18 (todas las versiones), SIRIUS Safety ES V17 (todas las versiones &lt; V17 Update 7), SIRIUS Safety ES V18 (todas las versiones &lt; V18 Update 2), SIRIUS Soft Starter ES V17 (todas las versiones &lt; V17 Update 7), SIRIUS Soft Starter ES V18 (Todas las versiones &lt; V18 Actualización 2), Soft Starter ES V16 (Todas las versiones &lt; V16 Actualización 7), TIA Portal Cloud V3.0 (Todas las versiones &lt; V18 Actualización 2). Las aplicaciones afectadas no restringen adecuadamente .NET BinaryFormatter al deserializar perfiles de configuración de hardware. • https://cert-portal.siemens.com/productcert/html/ssa-779936.html • CWE-502: Deserialization of Untrusted Data •

CVSS: 4.6EPSS: 0%CPEs: 36EXPL: 0

A vulnerability has been identified in SIMOTION C240 (All versions >= V5.4 < V5.5 SP1), SIMOTION C240 PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D410-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D425-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP (All versions >= V5.4 < V5.5 SP1), SIMOTION D435-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D445-2 DP/PN (All versions >= V5.4), SIMOTION D445-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION D455-2 DP/PN (All versions >= V5.4 < V5.5 SP1), SIMOTION P320-4 E (All versions >= V5.4), SIMOTION P320-4 S (All versions >= V5.4). When operated with Security Level Low the device does not protect access to certain services relevant for debugging. This could allow an unauthenticated attacker to extract confidential technology object (TO) configuration from the device. • https://cert-portal.siemens.com/productcert/pdf/ssa-482956.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-213: Exposure of Sensitive Information Due to Incompatible Policies •

CVSS: 6.5EPSS: 0%CPEs: 727EXPL: 0

Incomplete cleanup from specific special register read operations in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. Una limpieza incompleta de operaciones de lectura de un registro especial específico en algunos Intel® Processors puede permitir a un usuario autenticado habilitar potencialmente una divulgación de información por medio de un acceso local A new domain bypass transient execution attack known as Special Register Buffer Data Sampling (SRBDS) has been found. This flaw allows data values from special internal registers to be leaked by an attacker able to execute code on any core of the CPU. An unprivileged, local attacker can use this flaw to infer values returned by affected instructions known to be commonly used during cryptographic operations that rely on uniqueness, secrecy, or both. • http://lists.opensuse.org/opensuse-security-announce/2020-06/msg00025.html http://lists.opensuse.org/opensuse-security-announce/2020-07/msg00024.html http://lists.opensuse.org/opensuse-security-announce/2020-07/msg00031.html http://www.openwall.com/lists/oss-security/2020/07/14/5 https://cert-portal.siemens.com/productcert/pdf/ssa-534763.pdf https://kc.mcafee.com/corporate/index?page=content&id=SB10318 https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message • CWE-459: Incomplete Cleanup •

CVSS: 7.5EPSS: 0%CPEs: 98EXPL: 0

A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf https://cert-portal.siemens.com/productcert/html/ssa-349422.html • CWE-400: Uncontrolled Resource Consumption •