CVE-2024-23804
https://notcve.org/view.php?id=CVE-2024-23804
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted PSOBJ files. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix Plant Simulation V2302 (Toda... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVE-2024-23803
https://notcve.org/view.php?id=CVE-2024-23803
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones), Tecnomatix Plant Simulation V2302 (Todas ... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-787: Out-of-bounds Write •

CVE-2024-23802
https://notcve.org/view.php?id=CVE-2024-23802
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix ... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-125: Out-of-bounds Read •

CVE-2024-23801
https://notcve.org/view.php?id=CVE-2024-23801
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones), Tecnomatix Plant Simulation V2302 (T... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-476: NULL Pointer Dereference •

CVE-2024-23800
https://notcve.org/view.php?id=CVE-2024-23800
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones), Tecnomatix Plant Simulation V2302 (T... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-476: NULL Pointer Dereference •

CVE-2024-23799
https://notcve.org/view.php?id=CVE-2024-23799
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones), Tecnomatix Plant Simulation V2302 (T... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-476: NULL Pointer Dereference •

CVE-2024-23798 – Siemens Tecnomatix Plant Simulation WRL File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2024-23798
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix Plant Simulation V2302 (Todas ... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVE-2024-23797 – Siemens Tecnomatix Plant Simulation WRL File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2024-23797
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix Plant Simulation V2302 (Todas ... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVE-2024-23796 – Siemens Tecnomatix Plant Simulation WRL File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2024-23796
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix Plant Simulation V2302 (To... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVE-2024-23795 – Siemens Tecnomatix Plant Simulation WRL File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2024-23795
13 Feb 2024 — A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process. Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix P... • https://cert-portal.siemens.com/productcert/html/ssa-017796.html • CWE-787: Out-of-bounds Write •