34 results (0.010 seconds)

CVSS: 8.0EPSS: 0%CPEs: 1EXPL: 0

17 Apr 2024 — Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function. El firmware Tenda F1203 V2.0.1.6 tiene una vulnerabilidad de desbordamiento de pila ubicada en el parámetro PPW de la función fromWizardHandle. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/fromWizardHandle.md • CWE-121: Stack-based Buffer Overflow •

CVSS: 7.5EPSS: 0%CPEs: 1EXPL: 0

17 Apr 2024 — Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function. El firmware Tenda F1203 V2.0.1.6 tiene una vulnerabilidad de desbordamiento de pila ubicada en el parámetro adslPwd de la función formWanParameterSetting. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formWanParameterSetting.md • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

27 Mar 2024 — A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/setSchedWifi_end.md • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

27 Mar 2024 — A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formSetCfm.md • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

27 Mar 2024 — A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 1%CPEs: 1EXPL: 1

27 Mar 2024 — A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/R7WebsSecurityHandler.md • CWE-121: Stack-based Buffer Overflow •

CVSS: 10.0EPSS: 0%CPEs: 10EXPL: 1

07 Aug 2023 — Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md • CWE-787: Out-of-bounds Write •

CVSS: 10.0EPSS: 0%CPEs: 18EXPL: 1

07 Aug 2023 — Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md • CWE-787: Out-of-bounds Write •

CVSS: 10.0EPSS: 0%CPEs: 18EXPL: 1

07 Aug 2023 — Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md • CWE-787: Out-of-bounds Write •

CVSS: 10.0EPSS: 0%CPEs: 6EXPL: 1

07 Aug 2023 — Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetDeviceName/README.md • CWE-787: Out-of-bounds Write •