CVE-2020-8233
https://notcve.org/view.php?id=CVE-2020-8233
A command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges. Se presenta una vulnerabilidad de inyección de comandos en el firmware de EdgeSwitch versiones anteriores a v1.9.0, que permitía a un usuario autenticado de solo lectura ejecutar comandos de shell arbitrarios por medio de la interfaz HTTP, permitiéndoles escalar privilegios. • http://lists.opensuse.org/opensuse-security-announce/2020-10/msg00019.html https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821 https://www.ui.com/download/edgemax • CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •
CVE-2020-8232
https://notcve.org/view.php?id=CVE-2020-8232
An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages. Se presenta una vulnerabilidad de divulgación de información en el firmware EdgeMax EdgeSwitch versión v1.9.0, que permitía a unos usuarios de solo lectura poder obtener información no autorizada por medio de las páginas de una comunidad SNMP. • https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821 https://www.ui.com/download/edgemax • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •
CVE-2019-5446
https://notcve.org/view.php?id=CVE-2019-5446
Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root. Una Inyección de Comandos en EdgeMAX EdgeSwitch versiones anteriores a 1.8.2, permite a un usuario administrador ejecutar comandos como root. • https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7 • CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') •
CVE-2019-5445
https://notcve.org/view.php?id=CVE-2019-5445
DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands. Una DoS en EdgeMAX EdgeSwitch versiones anteriores a 1.8.2, permite que un usuario administrador Bloquee la interfaz de la CLI de SSH mediante el uso de comandos especialmente diseñados. • https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7 • CWE-400: Uncontrolled Resource Consumption •
CVE-2018-12591
https://notcve.org/view.php?id=CVE-2018-12591
Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an improperly neutralized element in an OS command due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary shell instructions. EdgeSwitch, de Ubiquiti Networks, en versiones 1.7.3 y anteriores sufre de un elemento neutralizado incorrectamente en un comando del sistema operativo debido a la falta de protección de la interfaz de línea de comandos admin. Esto conduce a la ejecución de código y a un escalado de privilegios mayor del que les está permitido a los propios administradores. Un atacante que cuente con acceso a una cuenta de administrador podría escapar de la interfaz de línea de comandos restringida y ejecutar instrucciones shell arbitrarias. • https://hackerone.com/reports/313245 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •