CVE-2020-8233
https://notcve.org/view.php?id=CVE-2020-8233
17 Aug 2020 — A command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges. Se presenta una vulnerabilidad de inyección de comandos en el firmware de EdgeSwitch versiones anteriores a v1.9.0, que permitía a un usuario autenticado de solo lectura ejecutar comandos de shell arbitrarios por medio de la interfaz HTTP, permitiéndoles escalar privilegios. • http://lists.opensuse.org/opensuse-security-announce/2020-10/msg00019.html • CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVE-2020-8232
https://notcve.org/view.php?id=CVE-2020-8232
17 Aug 2020 — An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages. Se presenta una vulnerabilidad de divulgación de información en el firmware EdgeMax EdgeSwitch versión v1.9.0, que permitía a unos usuarios de solo lectura poder obtener información no autorizada por medio de las páginas de una comunidad SNMP. • https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVE-2019-5446
https://notcve.org/view.php?id=CVE-2019-5446
10 Jul 2019 — Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root. Una Inyección de Comandos en EdgeMAX EdgeSwitch versiones anteriores a 1.8.2, permite a un usuario administrador ejecutar comandos como root. • https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7 • CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') •

CVE-2019-5445
https://notcve.org/view.php?id=CVE-2019-5445
10 Jul 2019 — DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands. Una DoS en EdgeMAX EdgeSwitch versiones anteriores a 1.8.2, permite que un usuario administrador Bloquee la interfaz de la CLI de SSH mediante el uso de comandos especialmente diseñados. • https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7 • CWE-400: Uncontrolled Resource Consumption •

CVE-2018-12590
https://notcve.org/view.php?id=CVE-2018-12590
20 Jun 2018 — Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary code. EdgeSwitch, de Ubiquiti Networks, en versiones 1.7.3 y anteriores sufre de una vulnerabilidad de cadena de formato controlada externamente debi... • https://hackerone.com/reports/311884 • CWE-134: Use of Externally-Controlled Format String •

CVE-2018-12591
https://notcve.org/view.php?id=CVE-2018-12591
20 Jun 2018 — Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an improperly neutralized element in an OS command due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary shell instructions. EdgeSwitch, de Ubiquiti Networks, en versiones 1.7.3 y anteriores sufre de un elemento neutralizado incorrectamente en un comando d... • https://hackerone.com/reports/313245 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •