CVSS: 4.9EPSS: 0%CPEs: 202EXPL: 0

Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a specifically crafted packet to the CODESYS V2 runtime. • https://cert.vde.com/en/advisories/VDE-2023-006 • CWE-20: Improper Input Validation •

CVSS: 4.9EPSS: 0%CPEs: 202EXPL: 0

Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a malformed packet. • https://cert.vde.com/en/advisories/VDE-2023-006 • CWE-20: Improper Input Validation •

CVSS: 9.1EPSS: 0%CPEs: 54EXPL: 0

On WAGO PFC200 devices in different firmware versions with special crafted packets an authorised attacker with network access to the device can access the file system with higher privileges. En los dispositivos WAGO PFC200 en diferentes versiones de firmware con paquetes especiales diseñados, un atacante autorizado con acceso de red al dispositivo puede acceder al sistema de archivos con mayores privilegios • https://cert.vde.com/en-us/advisories/vde-2021-014 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 7.5EPSS: 0%CPEs: 54EXPL: 0

On WAGO PFC200 devices in different firmware versions with special crafted packets an attacker with network access to the device could cause a denial of service for the login service of the runtime. En dispositivos WAGO PFC200 en diferentes versiones de firmware con paquetes especiales diseñados, un atacante con acceso de red al dispositivo podría causar una denegación de servicio para el servicio de inicio de sesión del tiempo de ejecución • https://cert.vde.com/en-us/advisories/vde-2021-014 • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 9.8EPSS: 0%CPEs: 19EXPL: 0

An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. Se ha descubierto un problema de autenticación indebida en WAGO PFC200 Series 3S CoDeSys Runtime, versiones 2.3.X y 2.4.X. Un atacante puede ejecutar diferentes operaciones remotas sin autenticación gracias a la aplicación CoDeSys Runtime, que está disponible en red por defecto en el puerto 2455. • https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01 • CWE-287: Improper Authentication •