CVE-2014-8514
Schneider Electric ProClima MetaDraw ObjLinks Property Remote Code Execution Vulnerability
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.
Desbordamiento de buffer en el control ActiveX en MDraw30.ocx en Schneider Electric ProClima anterior a 6.1.7 permite a atacantes remotos ejecutar código arbitrario a través de vectores sin especificar, una vulnerabilidad diferente a CVE-2014-8513 y CVE-2014-9188. NOTA: esto se puede aclarar después en base a los detalles proporcionados por los investigadores.
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric ProClima. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the MetaDraw ActiveX control's ObjLinks property. This property can be assigned an attacker-supplied memory address and the control will redirect execution flow to this given memory address. An attacker can exploit this condition to achieve code execution under the context of the browser process.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2014-10-28 CVE Reserved
- 2014-12-27 CVE Published
- 2024-08-06 CVE Updated
- 2024-09-22 EPSS Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
CAPEC
References (3)
URL | Tag | Source |
---|---|---|
http://www.securityfocus.com/bid/71710 | Vdb Entry |
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01 | 2016-12-31 | |
https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01 | 2016-12-31 |
URL | Date | SRC |
---|
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Schneider Electric Search vendor "Schneider Electric" | Proclima Search vendor "Schneider Electric" for product "Proclima" | <= 6.0.1 Search vendor "Schneider Electric" for product "Proclima" and version " <= 6.0.1" | - |
Affected
|