Descriptions

Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.

Siemens SIMATIC HMI Basic Panels 2nd Generation anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), y SIMATIC WinCC 7.x anterior a 7.3 Upd4 permiten a atacantes remotos completar la autenticación mediante el aprovechamiento de conocimiento de un hash de contraseñas sin conocer la contraseña asociada.

*Credits: N/A
CVSS Scores
Attack Vector
Network
Attack Complexity
Medium
Authentication
None
Confidentiality
Partial
Integrity
Partial
Availability
Partial
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2015-04-01 CVE Reserved
  • 2015-04-08 CVE Published
  • 2023-03-07 EPSS Updated
  • 2024-08-06 CVE Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
  • ---------- First Exploit
CWE
  • CWE-287: Improper Authentication
CAPEC
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Basic Panels Generation 1
Search vendor "Siemens" for product "Simatic Hmi Basic Panels Generation 1"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Basic Panels Generation 2
Search vendor "Siemens" for product "Simatic Hmi Basic Panels Generation 2"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Comfort Panels
Search vendor "Siemens" for product "Simatic Hmi Comfort Panels"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Mobile Panel 277
Search vendor "Siemens" for product "Simatic Hmi Mobile Panel 277"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Multi Panels
Search vendor "Siemens" for product "Simatic Hmi Multi Panels"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1, advanced
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Basic Panels Generation 1
Search vendor "Siemens" for product "Simatic Hmi Basic Panels Generation 1"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1, advanced
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Basic Panels Generation 2
Search vendor "Siemens" for product "Simatic Hmi Basic Panels Generation 2"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1, advanced
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Comfort Panels
Search vendor "Siemens" for product "Simatic Hmi Comfort Panels"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1, advanced
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Mobile Panel 277
Search vendor "Siemens" for product "Simatic Hmi Mobile Panel 277"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
<= 13.0
Search vendor "Siemens" for product "Wincc" and version " <= 13.0"
sp1, advanced
Affected
in Siemens
Search vendor "Siemens"
Simatic Hmi Multi Panels
Search vendor "Siemens" for product "Simatic Hmi Multi Panels"
*-
Safe
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
7.0
Search vendor "Siemens" for product "Wincc" and version "7.0"
-
Affected
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
7.1
Search vendor "Siemens" for product "Wincc" and version "7.1"
-
Affected
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
7.2
Search vendor "Siemens" for product "Wincc" and version "7.2"
-
Affected
Siemens
Search vendor "Siemens"
Wincc
Search vendor "Siemens" for product "Wincc"
7.3
Search vendor "Siemens" for product "Wincc" and version "7.3"
-
Affected