CVE-2015-7918
Schneider Electric ProClima F1BookView ActiveX Control SetTabbedTextEx Method Remote Code Execution Vulnerability
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.
Múltiples desbordamientos de buffer en el control F1BookView ActiveX en F1 Bookview en Schneider Electric ProClima en versiones anteriores a 6.2 permite atacantes remotos ejecutar código arbitrario a través del método (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx o (7) SetValidationRule, una vulnerabilidad diferente a CVE-2015-8561.
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric ProClima. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the implementation of the SetTabbedTextEx method of the F1BookView control. Memory corruption occurs when a long string is passed by the user to the method. An attacker could leverage this flaw to execute code under the context of the process.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2015-10-22 CVE Reserved
- 2015-12-08 CVE Published
- 2024-08-06 CVE Updated
- 2024-08-21 EPSS Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
CAPEC
References (9)
URL | Tag | Source |
---|---|---|
http://www.zerodayinitiative.com/advisories/ZDI-15-625 | X_refsource_misc | |
http://www.zerodayinitiative.com/advisories/ZDI-15-630 | X_refsource_misc | |
http://www.zerodayinitiative.com/advisories/ZDI-15-631 | X_refsource_misc | |
http://www.zerodayinitiative.com/advisories/ZDI-15-632 | X_refsource_misc | |
http://www.zerodayinitiative.com/advisories/ZDI-15-633 | X_refsource_misc | |
http://www.zerodayinitiative.com/advisories/ZDI-15-634 | X_refsource_misc | |
http://www.zerodayinitiative.com/advisories/ZDI-15-635 | X_refsource_misc | |
https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02 | Third Party Advisory |
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01 | 2015-12-16 |
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Schneider-electric Search vendor "Schneider-electric" | Proclima Search vendor "Schneider-electric" for product "Proclima" | <= 6.1 Search vendor "Schneider-electric" for product "Proclima" and version " <= 6.1" | - |
Affected
|