Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
Se ha determinado que ciertos mensajes de gestión de red 802.11 invocan defensas de seguridad de introducción en lista negra de puntos de acceso cuando no es necesario, lo que podría necesitar la intervención del personal hospitalario para restablecer el dispositivo y la conexión de red con el punto de acceso Wi-Fi. Durante este estado, Philips IntelliVue MX40 B.06.18 puede conectarse a un punto de acceso alternativo con un rango de señal para asociarlo a una estación central de monitorización o puede seguir en modo de monitorización local hasta que el personal hospitalario restablezca el dispositivo. Puntuación base de CVSS v3: 6.5, cadena de vector CVSS: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips ha lanzado una actualización de software, la versión B.06.18, para solucionar la vulnerabilidad de limpieza indebida de excepción lanzada. Además, también ha implementado mitigaciones para reducir el riesgo asociado con la vulnerabilidad de gestión incorrecta de condiciones excepcionales. La actualización de software implementa mensajes y alarmas en el MX40 y en la estación central de monitorización cuando el MX40 se desconecta del punto de acceso.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2017-06-14 CVE Reserved
- 2018-04-30 CVE Published
- 2023-10-31 EPSS Updated
- 2024-09-16 CVE Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-755: Improper Handling of Exceptional Conditions
CAPEC
References (3)
URL | Tag | Source |
---|---|---|
http://www.securityfocus.com/bid/100813 | Third Party Advisory | |
https://ics-cert.us-cert.gov/advisories/ICSMA-17-255-01 | Third Party Advisory |
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
https://www.usa.philips.com/healthcare/about/customer-support/product-security | 2019-10-09 |
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Philips Search vendor "Philips" | Intellivue Mx40 Firmware Search vendor "Philips" for product "Intellivue Mx40 Firmware" | < b.06.18 Search vendor "Philips" for product "Intellivue Mx40 Firmware" and version " < b.06.18" | - |
Affected
| in | Philips Search vendor "Philips" | Intellivue Mx40 Search vendor "Philips" for product "Intellivue Mx40" | - | - |
Safe
|