A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). By sending a specially crafted authentication request to the affected systems a remote attacker could escalate his privileges to an elevated user account but not to root. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Se ha identificado una vulnerabilidad en SINUMERIK 808D V4.7 (todas las versiones), SINUMERIK 808D V4.8 (todas las versiones), SINUMERIK 828D V4.7 (todas las versiones anteriores a la V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (todas las versiones anteriores a la V4.7 SP6 HF5) y SINUMERIK 840D sl V4.8 (todas las versiones anteriores a la V4.8 SP3). Mediante el envío de una petición de autenticación especialmente manipulada a los sistemas afectados, un atacante remoto podría escalar sus privilegios a una cuenta de usuario elevado, pero que no es root. Esta vulnerabilidad podría ser explotada por un atacante con acceso de red a los sistemas afectados. Su explotación con éxito no requiere privilegios de usuario ni interacción. Esta vulnerabilidad podría permitir que un atacante comprometa la confidencialidad, integridad y disponibilidad del sistema. En el momento de la publicación del advisory, no se conoce ninguna explotación pública de la vulnerabilidad de seguridad.

*Credits: N/A
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
Attack Vector
Network
Attack Complexity
Low
Authentication
None
Confidentiality
Partial
Integrity
Partial
Availability
Partial
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2018-05-25 CVE Reserved
  • 2018-12-12 CVE Published
  • 2024-05-04 EPSS Updated
  • 2024-08-05 CVE Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
  • ---------- First Exploit
CWE
  • CWE-264: Permissions, Privileges, and Access Controls
CAPEC
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Siemens
Search vendor "Siemens"
Sinumerik 808d V4.7 Firmware
Search vendor "Siemens" for product "Sinumerik 808d V4.7 Firmware"
*-
Affected
in Siemens
Search vendor "Siemens"
Sinumerik 808d V4.7
Search vendor "Siemens" for product "Sinumerik 808d V4.7"
--
Safe
Siemens
Search vendor "Siemens"
Sinumerik 808d V4.8 Firmware
Search vendor "Siemens" for product "Sinumerik 808d V4.8 Firmware"
*-
Affected
in Siemens
Search vendor "Siemens"
Sinumerik 808d V4.8
Search vendor "Siemens" for product "Sinumerik 808d V4.8"
--
Safe
Siemens
Search vendor "Siemens"
Sinumerik 828d V4.7 Firmware
Search vendor "Siemens" for product "Sinumerik 828d V4.7 Firmware"
<= 4.7
Search vendor "Siemens" for product "Sinumerik 828d V4.7 Firmware" and version " <= 4.7"
-
Affected
in Siemens
Search vendor "Siemens"
Sinumerik 828d V4.7
Search vendor "Siemens" for product "Sinumerik 828d V4.7"
--
Safe
Siemens
Search vendor "Siemens"
Sinumerik 840d Sl V4.7 Firmware
Search vendor "Siemens" for product "Sinumerik 840d Sl V4.7 Firmware"
<= 4.7
Search vendor "Siemens" for product "Sinumerik 840d Sl V4.7 Firmware" and version " <= 4.7"
-
Affected
in Siemens
Search vendor "Siemens"
Sinumerik 840d Sl V4.7
Search vendor "Siemens" for product "Sinumerik 840d Sl V4.7"
--
Safe
Siemens
Search vendor "Siemens"
Sinumerik 840d Sl V4.8 Firmware
Search vendor "Siemens" for product "Sinumerik 840d Sl V4.8 Firmware"
<= 4.8
Search vendor "Siemens" for product "Sinumerik 840d Sl V4.8 Firmware" and version " <= 4.8"
-
Affected
in Siemens
Search vendor "Siemens"
Sinumerik 840d Sl V4.8
Search vendor "Siemens" for product "Sinumerik 840d Sl V4.8"
--
Safe