// For flags

CVE-2018-14557

 

Severity Score

7.5
*CVSS v3

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

1
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

-
*SSVC
Descriptions

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow.

Se descubrió un problema en los dispositivos Tenda AC7 con firmware a través de la versión V15.03.06.44_CN (AC7), dispositivos AC9 con firmware a través de la versión V15.03.05.19 (6318) _CN (AC9), y dispositivos AC10 con firmware a través de la versión V15.03.06.23_CN ( AC10). Existe una vulnerabilidad de desbordamiento de búfer en el servidor web del router (httpd). Cuando son procesados los parámetros page para una solicitud post, el valor se escribe directamente con sprintf hacia una variable local colocada en la pila, que anula la dirección de retorno de la función, lo que provoca un desbordamiento del búfer.

*Credits: N/A
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High
Attack Vector
Network
Attack Complexity
Low
Authentication
None
Confidentiality
None
Integrity
None
Availability
Complete
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2018-07-23 CVE Reserved
  • 2019-04-25 CVE Published
  • 2024-08-05 CVE Updated
  • 2024-08-05 First Exploit
  • 2024-12-17 EPSS Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
CWE
  • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
CAPEC
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Tenda
Search vendor "Tenda"
Ac7 Firmware
Search vendor "Tenda" for product "Ac7 Firmware"
<= 15.03.06.44_cn
Search vendor "Tenda" for product "Ac7 Firmware" and version " <= 15.03.06.44_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac7
Search vendor "Tenda" for product "Ac7"
--
Safe
Tenda
Search vendor "Tenda"
Ac9 Firmware
Search vendor "Tenda" for product "Ac9 Firmware"
<= 15.03.05.19\(6318\)_cn
Search vendor "Tenda" for product "Ac9 Firmware" and version " <= 15.03.05.19\(6318\)_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac9
Search vendor "Tenda" for product "Ac9"
--
Safe
Tenda
Search vendor "Tenda"
Ac10 Firmware
Search vendor "Tenda" for product "Ac10 Firmware"
<= 15.03.06.23_cn
Search vendor "Tenda" for product "Ac10 Firmware" and version " <= 15.03.06.23_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac10
Search vendor "Tenda" for product "Ac10"
--
Safe