// For flags

CVE-2018-18731

 

Severity Score

7.5
*CVSS v3

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

1
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

-
*SSVC
Descriptions

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.

Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de búfer en el servidor web del router, httpd. Al procesar el parámetro deviceMac para una petición POST, el valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la dirección de retorno de la función.

*Credits: N/A
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High
Attack Vector
Network
Attack Complexity
Low
Authentication
None
Confidentiality
None
Integrity
None
Availability
Complete
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2018-10-27 CVE Reserved
  • 2018-10-28 CVE Published
  • 2024-08-05 CVE Updated
  • 2024-08-05 First Exploit
  • 2024-12-17 EPSS Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
CWE
  • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
CAPEC
References (1)
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Tenda
Search vendor "Tenda"
Ac7 Firmware
Search vendor "Tenda" for product "Ac7 Firmware"
15.03.06.44_cn
Search vendor "Tenda" for product "Ac7 Firmware" and version "15.03.06.44_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac7
Search vendor "Tenda" for product "Ac7"
--
Safe
Tenda
Search vendor "Tenda"
Ac9 Firmware
Search vendor "Tenda" for product "Ac9 Firmware"
15.03.05.19\(6318\)_cn
Search vendor "Tenda" for product "Ac9 Firmware" and version "15.03.05.19\(6318\)_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac9
Search vendor "Tenda" for product "Ac9"
--
Safe
Tenda
Search vendor "Tenda"
Ac10 Firmware
Search vendor "Tenda" for product "Ac10 Firmware"
15.03.06.23_cn
Search vendor "Tenda" for product "Ac10 Firmware" and version "15.03.06.23_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac10
Search vendor "Tenda" for product "Ac10"
--
Safe
Tenda
Search vendor "Tenda"
Ac15 Firmware
Search vendor "Tenda" for product "Ac15 Firmware"
15.03.05.19_cn
Search vendor "Tenda" for product "Ac15 Firmware" and version "15.03.05.19_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac15
Search vendor "Tenda" for product "Ac15"
--
Safe
Tenda
Search vendor "Tenda"
Ac18 Firmware
Search vendor "Tenda" for product "Ac18 Firmware"
15.03.05.19\(6318\)_cn
Search vendor "Tenda" for product "Ac18 Firmware" and version "15.03.05.19\(6318\)_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac18
Search vendor "Tenda" for product "Ac18"
--
Safe