CVE-2018-4842
 
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Se ha identificado una vulnerabilidad en la familia de conmutadores SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (todas las versiones inferiores a la versión V5.4.1), la familia de conmutadores SCALANCE X-300 (incluidas las variantes X408 y SIPLUS NET) (todas las versiones inferiores a la versión V4.1.3 ) Un atacante remoto y autenticado con acceso al servidor web de configuración podría almacenar el código del script en el sitio web, si la opción de redundancia HRP está configurada. Este código podría ejecutarse en el navegador web de las víctimas que visitan este sitio web (XSS), afectando su confidencialidad, integridad y disponibilidad. La interacción del usuario es necesaria para una explotación exitosa, ya que el usuario debe visitar el sitio web manipulado. En la etapa de publicación de este aviso de seguridad no se conoce explotación pública. El proveedor ha confirmado la vulnerabilidad y proporciona mitigaciones para resolverla.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2018-01-02 CVE Reserved
- 2018-06-14 CVE Published
- 2024-04-23 EPSS Updated
- 2024-08-05 CVE Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CAPEC
References (2)
URL | Tag | Source |
---|---|---|
https://www.securityfocus.com/bid/104494 | Vdb Entry |
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf | 2022-12-13 |
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Siemens Search vendor "Siemens" | Scalance X200irt Firmware Search vendor "Siemens" for product "Scalance X200irt Firmware" | < 5.4.1 Search vendor "Siemens" for product "Scalance X200irt Firmware" and version " < 5.4.1" | - |
Affected
| in | Siemens Search vendor "Siemens" | Scalance X200 Irt Search vendor "Siemens" for product "Scalance X200 Irt" | - | - |
Safe
|
Siemens Search vendor "Siemens" | Scalance X300 Firmware Search vendor "Siemens" for product "Scalance X300 Firmware" | - | - |
Affected
| in | Siemens Search vendor "Siemens" | Scalance X300 Search vendor "Siemens" for product "Scalance X300" | - | - |
Safe
|
Siemens Search vendor "Siemens" | Scalance X200 Firmware Search vendor "Siemens" for product "Scalance X200 Firmware" | < 5.2.3 Search vendor "Siemens" for product "Scalance X200 Firmware" and version " < 5.2.3" | - |
Affected
| in | Siemens Search vendor "Siemens" | Scalance X200 Search vendor "Siemens" for product "Scalance X200" | - | - |
Safe
|