CVE-2018-7530
OMRON CX-One CX-Protocol CObject Type Confusion Remote Code Execution Vulnerability
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may allow the pointer to call an incorrect object resulting in an access of resource using incompatible type condition.
El análisis sintáctico de archivos de proyecto mal formados en Omron CX-One, en versiones 4.42 y anteriores, incluyendo las siguientes aplicaciones: CX-FLnet, en versiones 1.00 y anteriores; CX-Protocol, en versiones 1.992 y anteriores; CX-Programmer, en versiones 9.65 y anteriores; CX-Server, en versiones 5.0.22 y anteriores; Network Configurator, en versiones 3.63 y anteriores y Switch Box Utility, en versiones 1.68 y anteriores, podría permitir que el puntero llame a un objeto incorrecto, lo que resulta en un acceso del recurso empleando una condición de tipo incompatible.
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of OMRON CX-One. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the processing of PSW files. When parsing a crafted file, the process does not properly validate user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code under the context of the current process.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2018-02-26 CVE Reserved
- 2018-04-11 CVE Published
- 2023-12-05 EPSS Updated
- 2024-09-16 CVE Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-118: Incorrect Access of Indexable Resource ('Range Error')
- CWE-843: Access of Resource Using Incompatible Type ('Type Confusion')
CAPEC
References (1)
URL | Tag | Source |
---|---|---|
https://ics-cert.us-cert.gov/advisories/ICSA-18-100-02 | Third Party Advisory |
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Omron Search vendor "Omron" | Cx-flnet Search vendor "Omron" for product "Cx-flnet" | <= 1.00 Search vendor "Omron" for product "Cx-flnet" and version " <= 1.00" | - |
Affected
| ||||||
Omron Search vendor "Omron" | Cx-one Search vendor "Omron" for product "Cx-one" | <= 4.42 Search vendor "Omron" for product "Cx-one" and version " <= 4.42" | - |
Affected
| ||||||
Omron Search vendor "Omron" | Cx-programmer Search vendor "Omron" for product "Cx-programmer" | <= 9.65 Search vendor "Omron" for product "Cx-programmer" and version " <= 9.65" | - |
Affected
| ||||||
Omron Search vendor "Omron" | Cx-protocol Search vendor "Omron" for product "Cx-protocol" | <= 1.992 Search vendor "Omron" for product "Cx-protocol" and version " <= 1.992" | - |
Affected
| ||||||
Omron Search vendor "Omron" | Cx-server Search vendor "Omron" for product "Cx-server" | <= 5.0.22 Search vendor "Omron" for product "Cx-server" and version " <= 5.0.22" | - |
Affected
| ||||||
Omron Search vendor "Omron" | Network Configurator Search vendor "Omron" for product "Network Configurator" | <= 3.63 Search vendor "Omron" for product "Network Configurator" and version " <= 3.63" | - |
Affected
| ||||||
Omron Search vendor "Omron" | Switch Box Utility Search vendor "Omron" for product "Switch Box Utility" | <= 1.68 Search vendor "Omron" for product "Switch Box Utility" and version " <= 1.68" | - |
Affected
|