On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover a data value. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. NOTE: the vendor's position is that there is no security impact: the only potentially leaked information is the number of characters in the PIN

** EN DISPUTA ** En los dispositivos BC Vault, se encontró un canal lateral para la pantalla OLED SSD1309 basada en filas. El consumo de energía de cada ciclo de visualización basado en filas depende del número de píxeles iluminados, lo que permite una recuperación parcial del contenido de la pantalla. Por ejemplo, un implante de hardware en el cable USB podría aprovechar este comportamiento para recuperar un valor de datos. En otras palabras, el canal lateral es relevante solo si el atacante tiene suficiente control sobre la conexión USB del dispositivo para realizar mediciones de consumo de energía en un momento en que se muestran datos secretos. El canal lateral no es relevante en otras circunstancias, como un dispositivo robado que actualmente no muestra datos secretos. NOTA: la posición del proveedor es que no hay impacto en la seguridad: la única información potencialmente filtrada es la cantidad de caracteres en el PIN.

*Credits: N/A
CVSS Scores
Attack Vector
Physical
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None
Attack Vector
Local
Attack Complexity
Low
Authentication
None
Confidentiality
Partial
Integrity
None
Availability
None
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2019-07-28 CVE Reserved
  • 2019-08-12 CVE Published
  • 2023-03-08 EPSS Updated
  • 2024-08-05 CVE Updated
  • 2024-08-05 First Exploit
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
CWE
  • CWE-203: Observable Discrepancy
CAPEC
References (1)
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Real-sec
Search vendor "Real-sec"
Bc Vault Firmware
Search vendor "Real-sec" for product "Bc Vault Firmware"
--
Affected
in Real-sec
Search vendor "Real-sec"
Bc Vault
Search vendor "Real-sec" for product "Bc Vault"
--
Safe