CVE-2019-6574
 
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Se ha identificado una vulnerabilidad en SINAMICS PERFECT HARMONY GH180 con control NXG I, MLFBs: 6SR2 ...-, 6SR3 ...-, 6SR4 ...- (Todas las versiones con opción G21, G22, G23, G26, G28, G31 , G32, G38, G43 o G46), SINAMICS PERFECT HARMONY GH180 con control NXG II, MLFBs: 6SR2 ...-, 6SR3 ...-, 6SR4 ...- (Todas las versiones con opción G21, G22, G23, G26 , G28, G31, G32, G38, G43 o G46). Una ejecución de lectura/escritura de parámetros configurada inapropiadamente a través de la red de bus de campo puede hacer que el controlador se reinicie. La vulnerabilidad podría ser explotada por un atacante con acceso de red al dispositivo. La explotación exitosa no requiere privilegios ni interacción con el usuario. Un atacante podría usar la vulnerabilidad para comprometer la disponibilidad del sistema afectado. Hasta el momento de la publicación de la asesoría, no se conocía aprovechamiento público de esta vulnerabilidad de seguridad.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2019-01-22 CVE Reserved
- 2019-05-14 CVE Published
- 2023-03-07 EPSS Updated
- 2024-08-04 CVE Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-200: Exposure of Sensitive Information to an Unauthorized Actor
CAPEC
References (1)
URL | Tag | Source |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-865156.pdf | 2020-10-06 |
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr2 Firmware Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr2 Firmware" | * | - |
Affected
| in | Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr2 Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr2" | - | - |
Safe
|
Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr3 Firmware Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr3 Firmware" | * | - |
Affected
| in | Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr3 Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr3" | - | - |
Safe
|
Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr4 Firmware Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr4 Firmware" | * | - |
Affected
| in | Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr4 Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr4" | - | - |
Safe
|
Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr2 Firmware Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr2 Firmware" | * | - |
Affected
| in | Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr2 Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr2" | - | - |
Safe
|
Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr3 Firmware Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr3 Firmware" | * | - |
Affected
| in | Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr3 Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr3" | - | - |
Safe
|
Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr4 Firmware Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr4 Firmware" | * | - |
Affected
| in | Siemens Search vendor "Siemens" | Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr4 Search vendor "Siemens" for product "Sinamics Perfect Harmony Gh180 With Nxg Ii Control Mlfb 6sr4" | - | - |
Safe
|