// For flags

CVE-2020-12028

Rockwell Automation FactoryTalk View SE

Severity Score

8.1
*CVSS v3.1

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

1
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

-
*SSVC
Descriptions

In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in security features found within FactoryTalk View SE. Users should follow guidance found in knowledge base articles 109056 and 1126943 to set up IPSec and/or HTTPs.

En todas las versiones de FactoryTalk View SEA un atacante autenticado remoto puede ser capaz de usar determinados manejadores para interactuar con los datos en el endpoint remoto, ya que esos controladores no aplican los permisos apropiados. Rockwell Automation recomienda habilitar las funciones de seguridad integradas que se encuentran en FactoryTalk View SE. Los usuarios deben seguir la guía que se encuentra en los artículos 109056 y 1126943 de la base de conocimiento para configurar IPSec y/o HTTP

This vulnerability allows remote attackers to create arbitrary files on affected installations of Rockwell Automation FactoryTalk View SE. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of project backups. The issue results from lack of authorization prior to initiating a backup. An attacker can leverage this in conjunction with other vulnerability to execute code in the context of SYSTEM.

*Credits: Trend Micro’s Zero Day Initiative reported these vulnerabilities to Rockwell Automation
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
Low
Attack Vector
Network
Attack Complexity
Low
Authentication
Single
Confidentiality
Partial
Integrity
Partial
Availability
None
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2020-04-21 CVE Reserved
  • 2020-06-22 CVE Published
  • 2024-09-16 CVE Updated
  • 2024-09-16 First Exploit
  • 2024-11-13 EPSS Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
CWE
  • CWE-264: Permissions, Privileges, and Access Controls
  • CWE-306: Missing Authentication for Critical Function
CAPEC
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Rockwellautomation
Search vendor "Rockwellautomation"
Factorytalk View
Search vendor "Rockwellautomation" for product "Factorytalk View"
*se
Affected