CVE-2020-26993
 
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CGM files. This could lead to a stack based buffer overflow while trying to copy to a buffer in the font index handling function. An attacker could leverage this vulnerability to execute code in the context of the current process.
Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.1.0), Teamcenter Visualization (Todas las versiones anteriores a V13.1.0). Las aplicaciones afectadas carecen de una comprobación apropiada de los datos proporcionados por el usuario al analizar archivos CGM. Esto podría conducir a un desbordamiento del búfer en la región stack de la memoria al intentar copiar a un búfer en la función de manejo del índice de fuentes. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual
CVSS Scores
SSVC
- Decision:-
Timeline
- 2020-10-12 CVE Reserved
- 2021-01-12 CVE Published
- 2023-12-19 EPSS Updated
- 2024-08-04 CVE Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-121: Stack-based Buffer Overflow
- CWE-787: Out-of-bounds Write
CAPEC
References (1)
URL | Tag | Source |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf | 2021-02-22 |
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Siemens Search vendor "Siemens" | Jt2go Search vendor "Siemens" for product "Jt2go" | < 13.1.0 Search vendor "Siemens" for product "Jt2go" and version " < 13.1.0" | - |
Affected
| ||||||
Siemens Search vendor "Siemens" | Teamcenter Visualization Search vendor "Siemens" for product "Teamcenter Visualization" | < 13.1.0 Search vendor "Siemens" for product "Teamcenter Visualization" and version " < 13.1.0" | - |
Affected
|