// For flags

CVE-2021-22761

Schneider Electric IGSS CGF File Parsing Memory Corruption Remote Code Execution Vulnerability

Severity Score

7.8
*CVSS v3.1

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

0
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

-
*SSVC
Descriptions

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.

Un CWE-119: Se presenta una vulnerabilidad de Restricción Inapropiada de las Operaciones dentro de los Límites de un Búfer de Memoria en IGSS Definition (Def.exe) versiones V15.0.0.21140 y anteriores que podría resultar en una divulgación de información o a una ejecución de código remota e+F15 debido a una falta de comprobación de la longitud de los datos suministrados por el usuario, cuando es importado un archivo CGF malicioso a IGSS Definition

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process.

*Credits: kimiya
CVSS Scores
Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
Attack Vector
Network
Attack Complexity
Medium
Authentication
None
Confidentiality
Partial
Integrity
Partial
Availability
Partial
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2021-01-06 CVE Reserved
  • 2021-06-10 CVE Published
  • 2024-05-30 EPSS Updated
  • 2024-08-03 CVE Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
  • ---------- First Exploit
CWE
  • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
CAPEC
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Schneider-electric
Search vendor "Schneider-electric"
Interactive Graphical Scada System
Search vendor "Schneider-electric" for product "Interactive Graphical Scada System"
<= 15.0.0.21140
Search vendor "Schneider-electric" for product "Interactive Graphical Scada System" and version " <= 15.0.0.21140"
-
Affected