// For flags

CVE-2021-26724

Authenticated command injection when changing date settings or hostname in Guardian/CMC before 20.0.7.4

Severity Score

8.6
*CVSS v4

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

0
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

-
*SSVC
Descriptions

OS Command Injection vulnerability when changing date settings or hostname using web GUI of Nozomi Networks Guardian and CMC allows authenticated administrators to perform remote code execution. This issue affects: Nozomi Networks Guardian 20.0.7.3 version 20.0.7.3 and prior versions. Nozomi Networks CMC 20.0.7.3 version 20.0.7.3 and prior versions.

Una vulnerabilidad de inyección de comandos del Sistema Operativo cuando se cambia la configuración de fecha o el nombre de host usando la GUI web de Nozomi Networks Guardian y CMC, permite a administradores autenticados llevar a cabo una ejecución de código remota . Este problema afecta a: Nozomi Networks Guardian versión 20.0.7.3 versión 20.0.7.3 y versiones anteriores. Nozomi Networks CMC versión 20.0.7.3 versión 20.0.7.3 y versiones anteriores

*Credits: This bug was found by Erik de Jong
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
System
Vulnerable | Subsequent
Confidentiality
High
None
Integrity
High
None
Availability
High
None
Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
Attack Vector
Network
Attack Complexity
Low
Authentication
Single
Confidentiality
Complete
Integrity
Complete
Availability
Complete
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2021-02-05 CVE Reserved
  • 2021-02-22 CVE Published
  • 2023-08-07 EPSS Updated
  • 2024-09-17 CVE Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
  • ---------- First Exploit
CWE
  • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CAPEC
  • CAPEC-88: OS Command Injection
References (1)
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Nozominetworks
Search vendor "Nozominetworks"
Central Management Control
Search vendor "Nozominetworks" for product "Central Management Control"
>= 19.0.0 <= 19.0.12
Search vendor "Nozominetworks" for product "Central Management Control" and version " >= 19.0.0 <= 19.0.12"
-
Affected
Nozominetworks
Search vendor "Nozominetworks"
Central Management Control
Search vendor "Nozominetworks" for product "Central Management Control"
>= 20.0.0.0 < 20.0.7.4
Search vendor "Nozominetworks" for product "Central Management Control" and version " >= 20.0.0.0 < 20.0.7.4"
-
Affected
Nozominetworks
Search vendor "Nozominetworks"
Guardian
Search vendor "Nozominetworks" for product "Guardian"
>= 19.0.0 < 19.0.12
Search vendor "Nozominetworks" for product "Guardian" and version " >= 19.0.0 < 19.0.12"
-
Affected
Nozominetworks
Search vendor "Nozominetworks"
Guardian
Search vendor "Nozominetworks" for product "Guardian"
>= 20.0.0.0 < 20.0.7.4
Search vendor "Nozominetworks" for product "Guardian" and version " >= 20.0.0.0 < 20.0.7.4"
-
Affected