CVE-2021-27382
Siemens Solid Edge Viewer DFT File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)
Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP14), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP4). Las aplicaciones afectadas carecen de la validación adecuada de los datos suministrados por el usuario al analizar los archivos PAR. Esto podría dar lugar a un desbordamiento del búfer basado en la pila. Un atacante podría aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. (ZDI-CAN-13040)
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the parsing of DFT files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2021-02-18 CVE Reserved
- 2021-04-22 CVE Published
- 2024-08-03 CVE Updated
- 2024-10-30 EPSS Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-121: Stack-based Buffer Overflow
- CWE-787: Out-of-bounds Write
CAPEC
References (3)
URL | Tag | Source |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06 | Third Party Advisory | |
https://www.zerodayinitiative.com/advisories/ZDI-21-612 | Third Party Advisory |
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf | 2021-12-15 |
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Siemens Search vendor "Siemens" | Solid Edge Se2020 Search vendor "Siemens" for product "Solid Edge Se2020" | <= se2020mp13 Search vendor "Siemens" for product "Solid Edge Se2020" and version " <= se2020mp13" | - |
Affected
| ||||||
Siemens Search vendor "Siemens" | Solid Edge Se2021 Search vendor "Siemens" for product "Solid Edge Se2021" | < se2021mp14 Search vendor "Siemens" for product "Solid Edge Se2021" and version " < se2021mp14" | - |
Affected
|