Privileged Command Injection Vulnerability in Fidelis Network and Deception

Severity Score

8.8
*CVSS v3.1

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

1
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

-
*SSVC
Descriptions

Vulnerability in the CommandPost, Collector, and Sensor components of Fidelis Network and Deception enables an attacker with user level access to the CLI to inject root level commands into the component and neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.3.7 and in version 9.4. Patches and updates are available to address this vulnerability.

Una vulnerabilidad en los componentes CommandPost, Collector y Sensor de Fidelis Network and Deception, permite a un atacante con acceso a nivel de usuario a la CLI inyectar comandos a nivel de root en el componente y en los componentes vecinos Fidelis. La vulnerabilidad está presente en Fidelis Network and Deception versiones anteriores a 9.3.7 y en versión 9.4. Se presentan parches y actualizaciones disponibles para solucionar esta vulnerabilidad

*Credits: Ryan Wincey(@rwincey) & Brandon Peterson(@Barbarisch926), Securifera
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High
Attack Vector
Network
Attack Complexity
Low
Authentication
Single
Confidentiality
Complete
Integrity
Complete
Availability
Complete
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2021-06-18 CVE Reserved
  • 2021-06-25 CVE Published
  • 2024-09-16 CVE Updated
  • 2024-09-16 First Exploit
  • 2024-12-17 EPSS Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
CWE
  • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CAPEC
References (1)
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Fidelissecurity
Search vendor "Fidelissecurity"
Deception
Search vendor "Fidelissecurity" for product "Deception"
< 9.3.7
Search vendor "Fidelissecurity" for product "Deception" and version " < 9.3.7"
-
Affected
Fidelissecurity
Search vendor "Fidelissecurity"
Deception
Search vendor "Fidelissecurity" for product "Deception"
9.4
Search vendor "Fidelissecurity" for product "Deception" and version "9.4"
-
Affected
Fidelissecurity
Search vendor "Fidelissecurity"
Network
Search vendor "Fidelissecurity" for product "Network"
< 9.3.7
Search vendor "Fidelissecurity" for product "Network" and version " < 9.3.7"
-
Affected
Fidelissecurity
Search vendor "Fidelissecurity"
Network
Search vendor "Fidelissecurity" for product "Network"
9.4
Search vendor "Fidelissecurity" for product "Network" and version "9.4"
-
Affected