// For flags

CVE-2022-39145

Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Read Remote Code Execution Vulnerability

Severity Score

7.8
*CVSS v3.1

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

0
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

-
*SSVC
Descriptions

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17496)

Se ha identificado una vulnerabilidad en Parasolid versiones V33.1 (Todas las versiones anteriores a V33.1.262), Parasolid versiones V33.1 (Todas las versiones posteriores a V33.1.262 incluyéndola, anteriores a V33.1.263), Parasolid versiones V34.0 (Todas las versiones anteriores a V34.0.252), Parasolid versiones V34.1 (Todas las versiones anteriores a V34. 1.242), Parasolid versiones V35.0 (Todas las versiones anteriores a V35.0.161), Parasolid versiones V35.0 (Todas las versiones posteriores a V35.0.161 incluyéndola, anteriores a V35.0.164), Simcenter Femap versiones V2022.1 (Todas las versiones anteriores a V2022.1.3), Simcenter Femap versiones V2022.2 (Todas las versiones anteriores a V2022.2.2). La aplicación afectada es vulnerable a la lectura fuera de límites más allá del final de un búfer asignado cuando son analizados archivos X_T. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-17496)

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the parsing of X_T files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process.

*Credits: Anonymous
CVSS Scores
Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2022-09-01 CVE Reserved
  • 2022-09-13 CVE Published
  • 2024-02-24 EPSS Updated
  • 2024-08-03 CVE Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
  • ---------- First Exploit
CWE
  • CWE-125: Out-of-bounds Read
CAPEC
References (1)
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Siemens
Search vendor "Siemens"
Simcenter Femap
Search vendor "Siemens" for product "Simcenter Femap"
>= 2022.1 < 2022.1.3
Search vendor "Siemens" for product "Simcenter Femap" and version " >= 2022.1 < 2022.1.3"
-
Affected
Siemens
Search vendor "Siemens"
Simcenter Femap
Search vendor "Siemens" for product "Simcenter Femap"
>= 2022.2 < 2022.2.2
Search vendor "Siemens" for product "Simcenter Femap" and version " >= 2022.2 < 2022.2.2"
-
Affected
Siemens
Search vendor "Siemens"
Parasolid
Search vendor "Siemens" for product "Parasolid"
>= 33.1 < 33.1.263
Search vendor "Siemens" for product "Parasolid" and version " >= 33.1 < 33.1.263"
-
Affected
Siemens
Search vendor "Siemens"
Parasolid
Search vendor "Siemens" for product "Parasolid"
>= 34.0 < 34.0.252
Search vendor "Siemens" for product "Parasolid" and version " >= 34.0 < 34.0.252"
-
Affected
Siemens
Search vendor "Siemens"
Parasolid
Search vendor "Siemens" for product "Parasolid"
>= 34.1 < 34.1.242
Search vendor "Siemens" for product "Parasolid" and version " >= 34.1 < 34.1.242"
-
Affected
Siemens
Search vendor "Siemens"
Parasolid
Search vendor "Siemens" for product "Parasolid"
>= 35.0 < 35.0.164
Search vendor "Siemens" for product "Parasolid" and version " >= 35.0 < 35.0.164"
-
Affected