CVE-2023-1133
CVE-2023-1133
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the installed instance of Apache ActiveMQ, which utilizes an outdated version of the JDK. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of an administrator.
Delta Electronics InfraSuite Device Master versions below 1.0.5 have an unauthenticated .NET deserialization vulnerability within the ParseUDPPacket() method of the Device-Gateway-Status process. The ParseUDPPacket() method reads user-controlled packet data and eventually calls BinaryFormatter.Deserialize() on what it determines to be the packet header without appropriate validation, leading to unauthenticated code execution as the user running the Device-Gateway-Status process.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2023-03-01 CVE Reserved
- 2023-03-27 CVE Published
- 2024-08-02 CVE Updated
- 2024-11-01 EPSS Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-502: Deserialization of Untrusted Data
CAPEC
References (4)
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Deltaww Search vendor "Deltaww" | Infrasuite Device Master Search vendor "Deltaww" for product "Infrasuite Device Master" | < 1.0.5 Search vendor "Deltaww" for product "Infrasuite Device Master" and version " < 1.0.5" | - |
Affected
|