// For flags

CVE-2023-2649

Tenda AC23 Service Port 7329 ate command injection

Severity Score

8.8
*CVSS v3.1

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

1
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

-
*SSVC
Descriptions

A vulnerability was found in Tenda AC23 16.03.07.45_cn. It has been declared as critical. This vulnerability affects unknown code of the file /bin/ate of the component Service Port 7329. The manipulation of the argument v2 leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-228778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

In Tenda AC23 16.03.07.45_cn wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um eine nicht genauer bekannte Funktion der Datei /bin/ate der Komponente Service Port 7329. Dank der Manipulation des Arguments v2 mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei über das Netzwerk erfolgen. Der Exploit steht zur öffentlichen Verfügung.

*Credits: dengxiquan
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
Attack Vector
Network
Attack Complexity
Low
Authentication
Multiple
Confidentiality
Complete
Integrity
Complete
Availability
Complete
* Common Vulnerability Scoring System
SSVC
  • Decision:-
Exploitation
-
Automatable
-
Tech. Impact
-
* Organization's Worst-case Scenario
Timeline
  • 2023-05-11 CVE Reserved
  • 2023-05-11 CVE Published
  • 2024-08-02 CVE Updated
  • 2024-08-02 First Exploit
  • 2024-10-21 EPSS Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
CWE
  • CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
CAPEC
References (2)
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Tenda
Search vendor "Tenda"
Ac23 Firmware
Search vendor "Tenda" for product "Ac23 Firmware"
16.03.07.45_cn
Search vendor "Tenda" for product "Ac23 Firmware" and version "16.03.07.45_cn"
-
Affected
in Tenda
Search vendor "Tenda"
Ac23
Search vendor "Tenda" for product "Ac23"
--
Safe