CVE-2023-38532
 
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.
Se ha identificado una vulnerabilidad en Parasolid V34.1 (Todas las versiones inferiores a V34.1.258), Parasolid V35.0 (Todas las versiones inferiores a V35.0.254), Parasolid V35.1 (Todas las versiones inferiores a V35.1. 171), Teamcenter Visualization V14.1 (Todas las versiones inferiores a V14.1.0.11), Teamcenter Visualization V14.2 (Todas las versiones inferiores a V14.2.0.6), Teamcenter Visualization V14.3 (Todas las versiones inferiores a V14.3.0.3). La aplicación afectada contiene una vulnerabilidad de agotamiento de pila al analizar un archivo X_T especialmente diseñado. Esto podría permitir a un atacante provocar una denegación de servicio.
CVSS Scores
SSVC
- Decision:-
Timeline
- 2023-07-19 CVE Reserved
- 2023-08-08 CVE Published
- 2024-08-13 CVE Updated
- 2024-09-09 EPSS Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-770: Allocation of Resources Without Limits or Throttling
CAPEC
References (2)
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf | 2024-06-11 |
URL | Date | SRC |
---|
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Siemens Search vendor "Siemens" | Parasolid Search vendor "Siemens" for product "Parasolid" | >= 34.1 < 34.1.258 Search vendor "Siemens" for product "Parasolid" and version " >= 34.1 < 34.1.258" | - |
Affected
| ||||||
Siemens Search vendor "Siemens" | Parasolid Search vendor "Siemens" for product "Parasolid" | >= 35.0 < 35.0.254 Search vendor "Siemens" for product "Parasolid" and version " >= 35.0 < 35.0.254" | - |
Affected
| ||||||
Siemens Search vendor "Siemens" | Parasolid Search vendor "Siemens" for product "Parasolid" | >= 35.1 < 35.1.171 Search vendor "Siemens" for product "Parasolid" and version " >= 35.1 < 35.1.171" | - |
Affected
| ||||||
Siemens Search vendor "Siemens" | Teamcenter Visualization Search vendor "Siemens" for product "Teamcenter Visualization" | >= 14.1 < 14.1.0.11 Search vendor "Siemens" for product "Teamcenter Visualization" and version " >= 14.1 < 14.1.0.11" | - |
Affected
| ||||||
Siemens Search vendor "Siemens" | Teamcenter Visualization Search vendor "Siemens" for product "Teamcenter Visualization" | >= 14.2 < 14.2.0.6 Search vendor "Siemens" for product "Teamcenter Visualization" and version " >= 14.2 < 14.2.0.6" | - |
Affected
| ||||||
Siemens Search vendor "Siemens" | Teamcenter Visualization Search vendor "Siemens" for product "Teamcenter Visualization" | >= 14.3 < 14.3.0.3 Search vendor "Siemens" for product "Teamcenter Visualization" and version " >= 14.3 < 14.3.0.3" | - |
Affected
|