CVE-2023-39461
Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
0Exploited in Wild
-Decision
Descriptions
Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535.
Triangle MicroWorks SCADA Data Gateway Registro de eventos Neutralización de salida inadecuada para registros Vulnerabilidad de escritura de archivos arbitrarios. Esta vulnerabilidad permite a atacantes remotos escribir archivos arbitrarios en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Aunque se requiere autenticación para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticación existente. La falla específica existe en el manejo de registros de eventos. El problema se debe a una sanitización inadecuada de la salida de registros. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar código en el contexto raíz. Era ZDI-CAN-20535.
This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root.
CVSS Scores
SSVC
- Decision:Track
Timeline
- 2023-08-02 CVE Reserved
- 2023-08-04 CVE Published
- 2024-05-03 EPSS Updated
- 2024-08-02 CVE Updated
- ---------- Exploited in Wild
- ---------- KEV Due Date
- ---------- First Exploit
CWE
- CWE-117: Improper Output Neutralization for Logs
CAPEC
References (2)
URL | Tag | Source |
---|---|---|
https://www.zerodayinitiative.com/advisories/ZDI-23-1029 | X_research Advisory |
URL | Date | SRC |
---|
URL | Date | SRC |
---|
URL | Date | SRC |
---|---|---|
https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new | 2024-05-03 |
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Triangle MicroWorks Search vendor "Triangle MicroWorks" | SCADA Data Gateway Search vendor "Triangle MicroWorks" for product "SCADA Data Gateway" | 5.1.3.20324 Search vendor "Triangle MicroWorks" for product "SCADA Data Gateway" and version "5.1.3.20324" | en |
Affected
|