A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.

Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones &lt; V7.5), SIMATIC Energy Manager PRO (todas las versiones &lt; V7.5), SIMATIC IPC DiagBase (todas las versiones), SIMATIC IPC DiagMonitor (todas las versiones), SIMIT V10 (Todas las versiones), SIMIT V11 (Todas las versiones &lt; V11.1). El SDK del servidor OPC UA basado en Unified Automation .NET anterior a 3.2.2 utilizado en productos Siemens se ve afectado por una vulnerabilidad similar a la documentada en CVE-2023-27321 para la implementación del estándar OPC Foundation UA .NET. Un ataque exitoso puede provocar una situación de carga elevada y agotamiento de la memoria, y puede bloquear el servidor.

*Credits: N/A
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
Low
Attack Vector
Network
Attack Complexity
Low
Authentication
None
Confidentiality
Partial
Integrity
None
Availability
None
* Common Vulnerability Scoring System
SSVC
  • Decision:Attend
Exploitation
None
Automatable
Yes
Tech. Impact
Partial
* Organization's Worst-case Scenario
Timeline
  • 2024-06-21 CVE Reserved
  • 2024-07-09 CVE Published
  • 2024-08-02 CVE Updated
  • 2025-04-15 EPSS Updated
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
  • ---------- First Exploit
CWE
  • CWE-1325: Improperly Controlled Sequential Memory Allocation
CAPEC
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Siemens
Search vendor "Siemens"
SIMATIC IPC DiagBase
Search vendor "Siemens" for product "SIMATIC IPC DiagBase"
0
Search vendor "Siemens" for product "SIMATIC IPC DiagBase" and version "0"
en
Affected
Siemens
Search vendor "Siemens"
SIMATIC IPC DiagMonitor
Search vendor "Siemens" for product "SIMATIC IPC DiagMonitor"
0
Search vendor "Siemens" for product "SIMATIC IPC DiagMonitor" and version "0"
en
Affected
Siemens
Search vendor "Siemens"
SIMIT V10
Search vendor "Siemens" for product "SIMIT V10"
0
Search vendor "Siemens" for product "SIMIT V10" and version "0"
en
Affected