CVE-2024-11676
CodeAstro Hospital Management System Add Laboratory Equipment Page his_admin_add_lab_equipment.php cross site scripting
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
1Exploited in Wild
-Decision
Descriptions
A vulnerability was found in CodeAstro Hospital Management System 1.0 and classified as problematic. Affected by this issue is some unknown functionality of the file /backend/admin/his_admin_add_lab_equipment.php of the component Add Laboratory Equipment Page. The manipulation of the argument eqp_code/eqp_name/eqp_vendor/eqp_desc/eqp_dept/eqp_status/eqp_qty leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Se encontró una vulnerabilidad en CodeAstro Hospital Management System 1.0 y se clasificó como problemática. Este problema afecta a algunas funciones desconocidas del archivo /backend/admin/his_admin_add_lab_equipment.php del componente Add Laboratory Equipment Page. La manipulación del argumento eqp_code/eqp_name/eqp_vendor/eqp_desc/eqp_dept/eqp_status/eqp_qty genera cross-site scripting. El ataque puede ejecutarse de forma remota. El exploit se ha revelado al público y puede utilizarse.
Eine Schwachstelle wurde in CodeAstro Hospital Management System 1.0 gefunden. Sie wurde als problematisch eingestuft. Es geht hierbei um eine nicht näher spezifizierte Funktion der Datei /backend/admin/his_admin_add_lab_equipment.php der Komponente Add Laboratory Equipment Page. Mittels dem Manipulieren des Arguments eqp_code/eqp_name/eqp_vendor/eqp_desc/eqp_dept/eqp_status/eqp_qty mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk angegangen werden. Der Exploit steht zur öffentlichen Verfügung.
CVSS Scores
SSVC
- Decision:Track*
Timeline
- 2024-11-25 CVE Reserved
- 2024-11-26 CVE Published
- 2024-11-26 CVE Updated
- 2024-11-26 EPSS Updated
- 2024-11-26 First Exploit
- ---------- Exploited in Wild
- ---------- KEV Due Date
CWE
- CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
- CWE-94: Improper Control of Generation of Code ('Code Injection')
CAPEC
References (4)
URL | Tag | Source |
---|---|---|
https://codeastro.com | Product | |
https://vuldb.com/?id.286016 | Technical Description | |
https://www.youtube.com/watch?v=UsScmd8Xzuw | Media Coverage |
URL | Date | SRC |
---|---|---|
https://github.com/EmilGallajov/zero-day/blob/main/codeastro_hms_stored_xss.md | 2024-11-26 |
URL | Date | SRC |
---|
URL | Date | SRC |
---|
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
CodeAstro Search vendor "CodeAstro" | Hospital Management System Search vendor "CodeAstro" for product "Hospital Management System" | 1.0 Search vendor "CodeAstro" for product "Hospital Management System" and version "1.0" | en |
Affected
|