// For flags

CVE-2024-2992

Tenda FH1203 setcfm formSetCfm stack-based overflow

Severity Score

8.8
*CVSS v3.1

Exploit Likelihood

*EPSS

Affected Versions

*CPE

Public Exploits

1
*Multiple Sources

Exploited in Wild

-
*KEV

Decision

Attend
*SSVC
Descriptions

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Una vulnerabilidad fue encontrada en Tenda FH1203 2.0.1.6 y clasificada como crítica. Este problema afecta a la función formSetCfm del archivo /goform/setcfm. La manipulación del argumento funcpara1 provoca un desbordamiento de búfer en la región stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. A esta vulnerabilidad se le asignó el identificador VDB-258161. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.

Eine kritische Schwachstelle wurde in Tenda FH1203 2.0.1.6 gefunden. Es geht hierbei um die Funktion formSetCfm der Datei /goform/setcfm. Mit der Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk angegangen werden. Der Exploit steht zur öffentlichen Verfügung.

*Credits: wxhwxhwxh_tu
CVSS Scores
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
Attack Vector
Network
Attack Complexity
Low
Authentication
Single
Confidentiality
Complete
Integrity
Complete
Availability
Complete
* Common Vulnerability Scoring System
SSVC
  • Decision:Attend
Exploitation
Poc
Automatable
No
Tech. Impact
Total
* Organization's Worst-case Scenario
Timeline
  • 2024-03-27 CVE Reserved
  • 2024-03-27 CVE Published
  • 2024-03-28 EPSS Updated
  • 2024-08-01 CVE Updated
  • 2024-08-01 First Exploit
  • ---------- Exploited in Wild
  • ---------- KEV Due Date
CWE
  • CWE-121: Stack-based Buffer Overflow
CAPEC
Affected Vendors, Products, and Versions
Vendor Product Version Other Status
Vendor Product Version Other Status <-- --> Vendor Product Version Other Status
Tenda
Search vendor "Tenda"
FH1203
Search vendor "Tenda" for product "FH1203"
2.0.1.6
Search vendor "Tenda" for product "FH1203" and version "2.0.1.6"
en
Affected