CVE-2024-4124
Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow
Severity Score
Exploit Likelihood
Affected Versions
Public Exploits
1Exploited in Wild
-Decision
Descriptions
A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Una vulnerabilidad fue encontrada en Tenda W15E 15.11.0.14 y clasificada como crítica. Esto afecta a la función formSetRemoteWebManage del archivo /goform/SetRemoteWebManage. La manipulación del argumento IP remota conduce a un desbordamiento de búfer en la región stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-261867. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.
Es wurde eine kritische Schwachstelle in Tenda W15E 15.11.0.14 gefunden. Es geht dabei um die Funktion formSetRemoteWebManage der Datei /goform/SetRemoteWebManage. Dank Manipulation des Arguments remoteIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk passieren. Der Exploit steht zur öffentlichen Verfügung.
CVSS Scores
SSVC
- Decision:Attend
Timeline
- 2024-04-24 CVE Reserved
- 2024-04-24 CVE Published
- 2024-04-25 EPSS Updated
- 2024-08-01 CVE Updated
- 2024-08-01 First Exploit
- ---------- Exploited in Wild
- ---------- KEV Due Date
CWE
- CWE-121: Stack-based Buffer Overflow
CAPEC
References (3)
URL | Tag | Source |
---|---|---|
https://vuldb.com/?id.261867 | Technical Description | |
https://vuldb.com/?submit.317829 | Third Party Advisory |
URL | Date | SRC |
---|---|---|
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetRemoteWebManage.md | 2024-08-01 |
URL | Date | SRC |
---|
URL | Date | SRC |
---|
Affected Vendors, Products, and Versions
Vendor | Product | Version | Other | Status | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Vendor | Product | Version | Other | Status | <-- --> | Vendor | Product | Version | Other | Status |
Tenda Search vendor "Tenda" | W15E Search vendor "Tenda" for product "W15E" | 15.11.0.14 Search vendor "Tenda" for product "W15E" and version "15.11.0.14" | en |
Affected
|