CVE-2024-2453 – Advantech WebAccess/SCADA SQL Injection
https://notcve.org/view.php?id=CVE-2024-2453
There is an SQL injection vulnerability in Advantech WebAccess/SCADA software that allows an authenticated attacker to remotely inject SQL code in the database. Successful exploitation of this vulnerability could allow an attacker to read or modify data on the remote database. Existe una vulnerabilidad de inyección SQL en el software Advantech WebAccess/SCADA que permite a un atacante autenticado inyectar código SQL de forma remota en la base de datos. La explotación exitosa de esta vulnerabilidad podría permitir a un atacante leer o modificar datos en la base de datos remota. • https://www.cisa.gov/news-events/ics-advisories/icsa-24-081-01 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •
CVE-2023-4215 – Advantech WebAccess Debug Messages Revealing Unnecessary Information
https://notcve.org/view.php?id=CVE-2023-4215
Advantech WebAccess version 9.1.3 contains an exposure of sensitive information to an unauthorized actor vulnerability that could leak user credentials. Advantech WebAccess versión 9.1.3 contiene una exposición de información confidencial a una vulnerabilidad de un actor no autorizado que podría filtrar las credenciales del usuario. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-15 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-1295: Debug Messages Revealing Unnecessary Information •
CVE-2023-1437 – CVE-2023-1437
https://notcve.org/view.php?id=CVE-2023-1437
All versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. The RPC arguments the client sent could contain raw memory pointers for the server to use as-is. This could allow an attacker to gain access to the remote file system and the ability to execute commands and overwrite files. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-822: Untrusted Pointer Dereference •
CVE-2023-2866 – Advantech WebAccess Insufficient Type Distinction
https://notcve.org/view.php?id=CVE-2023-2866
If an attacker can trick an authenticated user into loading a maliciously crafted .zip file onto Advantech WebAccess version 8.4.5, a web shell could be used to give the attacker full control of the SCADA server. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-150-01 • CWE-345: Insufficient Verification of Data Authenticity CWE-351: Insufficient Type Distinction •
CVE-2023-22450
https://notcve.org/view.php?id=CVE-2023-22450
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attacker to upload an ASP script file to a webserver when logged in as manager user, which can lead to arbitrary code execution. • https://www.cisa.gov/news-events/ics-advisories/icsa-23-152-01 • CWE-434: Unrestricted Upload of File with Dangerous Type •