14 results (0.006 seconds)

CVSS: 8.8EPSS: 0%CPEs: 1EXPL: 0

31 Aug 2020 — Improper Input Validation vulnerability exists in PowerChute Business Edition (software V9.0.x and earlier) which could cause remote code execution when a script is executed during a shutdown event. Se presenta una vulnerabilidad de Comprobación de Entrada Inapropiada en PowerChute Business Edition (versiones de software V9.0.x y anteriores) que podría causar una ejecución de código remota cuando es ejecutado un script durante un evento de apagado • https://www.se.com/ww/en/download/document/SEVD-2020-224-05 • CWE-20: Improper Input Validation •

CVSS: 6.1EPSS: 0%CPEs: 4EXPL: 0

07 Dec 2011 — Cross-site scripting (XSS) vulnerability in Schneider Electric PowerChute Business Edition before 8.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. Vulnerabilidad de ejecución de secuencias de comandos en sitios cruzados (XSS) en Schneider Electric PowerChute Business Edition antes de v8.5, permite a atacantes remotos inyectar secuencias de comandos web o HTML a través de vectores no especificados. • http://jvn.jp/en/jp/JVN61695284/index.html • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.1EPSS: 0%CPEs: 2EXPL: 1

28 Dec 2009 — Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to inject arbitrary web script or HTML via unspecified vectors. NOTE: the login_username vector for Forms/login1 is already covered by CVE-2009-4406. Múltiples vulnerabilidades de secuencias de comandos en sitios cruzados (XSS) en Network Management Card (NMC) para dispositivos Americ... • https://www.exploit-db.com/exploits/33405 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 8.8EPSS: 0%CPEs: 2EXPL: 0

28 Dec 2009 — Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to hijack the authentication of (1) administrator or (2) device users for requests that create new administrative users or have unspecified other impact. Múltiples vulnerabilidades de falsificación de petición en sitios cruzados (CSRF) en Network Management Card (NMC) para disp... • http://holisticinfosec.org/content/view/111/45 • CWE-352: Cross-Site Request Forgery (CSRF) •

CVSS: 6.1EPSS: 1%CPEs: 4EXPL: 2

23 Dec 2009 — Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the login_username parameter. Vulnerabilidad de secuencias de comandos en sitios cruzados (XSS) en Forms/login1 en American Power Conversion (APC) Switched Rack PDU AP7932 B2, ejecutando rpdu v3.3.3 o v3.7.0 en AOS v3.3.4, y probablemente otras versione... • http://www.packetstormsecurity.org/0912-exploits/apc-xss.txt • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 9.8EPSS: 6%CPEs: 2EXPL: 0

04 Dec 2007 — The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login attempt once the other client exits. La American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), con rpdu 3.5.5 y aos 3.5.6, permite a atacantes remotos evitar la validación y ob... • http://securityreason.com/securityalert/3418 • CWE-287: Improper Authentication •

CVSS: 9.1EPSS: 0%CPEs: 1EXPL: 0

17 Dec 2005 — The web interface for American Power Conversion (APC) PowerChute Network Shutdown performs all communication in cleartext (base64-encoded), which allows remote attackers to sniff authentication credentials. • http://nam-en.apc.com/cgi-bin/nam_en.cfg/php/enduser/std_adp.php?p_faqid=7330 •

CVSS: 7.5EPSS: 1%CPEs: 2EXPL: 0

31 Dec 2004 — Unknown vulnerability in APC PowerChute Business Edition 6.0 through 7.0.1 allows remote attackers to cause a denial of service via unknown attack vectors. • http://marc.info/?l=bugtraq&m=109061480026378&w=2 •

CVSS: 10.0EPSS: 1%CPEs: 2EXPL: 0

18 Mar 2004 — American Power Conversion (APC) Web/SNMP Management SmartSlot Card 3.0 through 3.0.3 and 3.21 are shipped with a default password of TENmanUFactOryPOWER, which allows remote attackers to gain unauthorized access. • http://marc.info/?l=bugtraq&m=107703696631367&w=2 •

CVSS: 9.8EPSS: 0%CPEs: 1EXPL: 0

26 Feb 2003 — Multiple buffer overflows in apcupsd before 3.8.6, and 3.10.x before 3.10.5, may allow attackers to cause a denial of service or execute arbitrary code, related to usage of the vsprintf function. Múltiples desbordamientos de búfer en apcupsd anteriores a 3.10.5 pueden permitir a atacantes causar una denegación de servicio o ejecutar código arbitrario, relacionado con el uso de la función vsprintf. • ftp://ftp.caldera.com/pub/security/OpenLinux/CSSA-2003-015.0.txt •