15 results (0.023 seconds)

CVSS: 7.5EPSS: 0%CPEs: 101EXPL: 0

On the affected platforms running EOS, a malformed DHCP packet might cause the DHCP relay agent to restart. • https://www.arista.com/en/support/advisories-notices/security-advisory/17445-security-advisory-0087 • CWE-755: Improper Handling of Exceptional Conditions •

CVSS: 8.8EPSS: 0%CPEs: 113EXPL: 1

On affected platforms running Arista EOS, an authorized attacker with permissions to perform gNMI requests could craft a request allowing it to update arbitrary configurations in the switch. This situation occurs only when the Streaming Telemetry Agent (referred to as the TerminAttr agent) is enabled and gNMI access is configured on the agent. Note: This gNMI over the Streaming Telemetry Agent scenario is mostly commonly used when streaming to a 3rd party system and is not used by default when streaming to CloudVision • https://www.arista.com/en/support/advisories-notices/security-advisory/17250-security-advisory-0086 • CWE-284: Improper Access Control CWE-863: Incorrect Authorization •

CVSS: 9.3EPSS: 0%CPEs: 26EXPL: 1

On affected modular platforms running Arista EOS equipped with both redundant supervisor modules and having the redundancy protocol configured with RPR or SSO, an existing unprivileged user can login to the standby supervisor as a root user, leading to a privilege escalation. Valid user credentials are required in order to exploit this vulnerability. • https://www.arista.com/en/support/advisories-notices/security-advisory/16985-security-advisory-0082 • CWE-269: Improper Privilege Management •

CVSS: 7.5EPSS: 0%CPEs: 114EXPL: 1

On affected platforms running Arista EOS with SNMP configured, a specially crafted packet can cause a memory leak in the snmpd process. This may result in the snmpd processing being terminated (causing SNMP requests to time out until snmpd is automatically restarted) and potential memory resource exhaustion for other processes on the switch. The vulnerability does not have any confidentiality or integrity impacts to the system. • https://www.arista.com/en/support/advisories-notices/security-advisory/17239-security-advisory-0084 • CWE-401: Missing Release of Memory after Effective Lifetime •

CVSS: 7.5EPSS: 0%CPEs: 81EXPL: 1

For certain systems running EOS, a Precision Time Protocol (PTP) packet of a management/signaling message with an invalid Type-Length-Value (TLV) causes the PTP agent to restart. Repeated restarts of the service will make the service unavailable. • https://www.arista.com/en/support/advisories-notices/security-advisory/15439-security-advisory-0076 • CWE-400: Uncontrolled Resource Consumption CWE-1284: Improper Validation of Specified Quantity in Input •