45 results (0.038 seconds)

CVSS: 9.8EPSS: 0%CPEs: 2EXPL: 0

An issue in Contec SolarView Compact v.6.0 and before allows an attacker to execute arbitrary code via the texteditor.php component. Un problema en Contec SolarView Compact v.6.0 y anteriores permite a un atacante ejecutar código arbitrario a través del componente texteditor.php. • https://gist.github.com/ATonysan/d6f72e9eb90407d64bed4566aa80afb1#file-cve-2023-46509 • CWE-94: Improper Control of Generation of Code ('Code Injection') •

CVSS: 7.5EPSS: 0%CPEs: 2EXPL: 2

SolarView Compact < 6.00 is vulnerable to Directory Traversal. SolarView Compact &lt; 6.00 es vulnerable a Directory Traversal. • https://github.com/Yobing1/CVE-2023-40924 https://github.com/Yobing1/CVE-2023-40924/blob/main/README.md https://nvd.nist.gov/vuln/detail/CVE-2023-33620 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program. • https://jvn.jp/en/vu/JVNVU93372935 https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf • CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 4.8EPSS: 0%CPEs: 1EXPL: 0

Cross-site scripting vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is accessing the affected product with an administrative privilege. • https://jvn.jp/en/vu/JVNVU93372935 https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 8.8EPSS: 0%CPEs: 1EXPL: 0

Improper access control vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user. • https://jvn.jp/en/vu/JVNVU93372935 https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf •