45 results (0.003 seconds)

CVSS: 9.8EPSS: 0%CPEs: 2EXPL: 0

An issue in Contec SolarView Compact v.6.0 and before allows an attacker to execute arbitrary code via the texteditor.php component. Un problema en Contec SolarView Compact v.6.0 y anteriores permite a un atacante ejecutar código arbitrario a través del componente texteditor.php. • https://gist.github.com/ATonysan/d6f72e9eb90407d64bed4566aa80afb1#file-cve-2023-46509 • CWE-94: Improper Control of Generation of Code ('Code Injection') •

CVSS: 7.5EPSS: 0%CPEs: 2EXPL: 2

SolarView Compact < 6.00 is vulnerable to Directory Traversal. SolarView Compact &lt; 6.00 es vulnerable a Directory Traversal. • https://github.com/Yobing1/CVE-2023-40924 https://github.com/Yobing1/CVE-2023-40924/blob/main/README.md https://nvd.nist.gov/vuln/detail/CVE-2023-33620 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 8.8EPSS: 0%CPEs: 1EXPL: 0

Improper access control vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user. • https://jvn.jp/en/vu/JVNVU93372935 https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf •

CVSS: 4.8EPSS: 0%CPEs: 1EXPL: 0

Cross-site scripting vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is accessing the affected product with an administrative privilege. • https://jvn.jp/en/vu/JVNVU93372935 https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 7.2EPSS: 0%CPEs: 1EXPL: 0

SQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page. • https://jvn.jp/en/vu/JVNVU93372935 https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •