CVE-2022-31233
https://notcve.org/view.php?id=CVE-2022-31233
Unisphere for PowerMax versions before 9.2.3.15 contain a privilege escalation vulnerability. An adjacent malicious user may potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. Unisphere for PowerMax versiones anteriores a 9.2.3.15, contienen una vulnerabilidad de escalada de privilegios. Un usuario malicioso adyacente puede explotar potencialmente esta vulnerabilidad para escalar sus privilegios y acceder a funcionalidades a las que no presenta acceso • https://www.dell.com/support/kbdoc/000200975 • CWE-602: Client-Side Enforcement of Server-Side Security CWE-669: Incorrect Resource Transfer Between Spheres •
CVE-2021-36339
https://notcve.org/view.php?id=CVE-2021-36339
The Dell EMC Virtual Appliances before 9.2.2.2 contain undocumented user accounts. A local malicious user may potentially exploit this vulnerability to get privileged access to the virtual appliance. Los dispositivos virtuales de Dell EMC versiones anteriores a 9.2.2.2, contienen cuentas de usuario no documentadas. Un usuario local malicioso puede explotar potencialmente esta vulnerabilidad para conseguir acceso privilegiado al dispositivo virtual • https://www.dell.com/support/kbdoc/000194640 • CWE-250: Execution with Unnecessary Privileges •
CVE-2021-36338
https://notcve.org/view.php?id=CVE-2021-36338
Unisphere for PowerMax versions prior to 9.2.2.2 contains a privilege escalation vulnerability. An adjacent malicious user could potentially exploit this vulnerability to escalate their privileges and access functionalities they do not have access to. CVE-2022-31233 addresses the partial fix in CVE-2021-36338. Las versiones de Unisphere for PowerMax anteriores a la 9.2.2.2 contienen una vulnerabilidad de escalada de privilegios. Un usuario malintencionado adyacente podría explotar esta vulnerabilidad para escalar sus privilegios y acceder a funcionalidades a las que no tiene acceso. • https://www.dell.com/support/kbdoc/000194640 • CWE-565: Reliance on Cookies without Validation and Integrity Checking CWE-602: Client-Side Enforcement of Server-Side Security •
CVE-2017-14375 – EMC Unisphere For VMAX vApp Manager ORBServlet Remote Credential Creation Information Disclosure Vulnerability
https://notcve.org/view.php?id=CVE-2017-14375
EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, and EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier) contain an authentication bypass vulnerability that may potentially be exploited by malicious users to compromise the affected system. EMC Unisphere para VMAX Virtual Appliance (vApp) en versiones anteriores a la 8.4.0.15, EMC Solutions Enabler Virtual Appliance en versiones anteriores a la 8.4.0.15, EMC VASA Virtual Appliance en versiones anteriores a la 8.4.0.512, y EMC VMAX Embedded Management (eManagement) en su versión 1.4 y anteriores (Enginuity Release 5977.1125.1125 y anteriores) contiene una vulnerabilidad de omisión de autenticación que podría ser explotada por usuarios maliciosos con el fin de comprometer el sistema afectado. This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of EMC Unisphere For VMAX vApp Manager. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ORBServlet. The vulnerability is caused by improper access controls that allow the creation of admin credentials. • http://seclists.org/fulldisclosure/2017/Oct/70 http://www.securityfocus.com/bid/101673 http://www.securitytracker.com/id/1039704 • CWE-290: Authentication Bypass by Spoofing •