8 results (0.065 seconds)

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

07 Dec 2022 — GE CIMPICITY versions 2022 and prior is vulnerable to an out-of-bounds write, which could allow an attacker to execute arbitrary code. Las versiones 2022 y anteriores de GE CIMPICITY son vulnerables a una escritura fuera de los límites, lo que podría permitir a un atacante ejecutar código arbitrario. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04 • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

07 Dec 2022 — GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiRootOptionTable, which could allow an attacker to execute arbitrary code. GE CIMPICITY versiones 2022 y anteriores es vulnerable cuando los datos de una dirección defectuosa controlan el flujo de código a partir de gmmiObj!CGmmiRootOptionTable, lo que podría permitir a un atacante ejecutar código arbitrario. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04 • CWE-824: Access of Uninitialized Pointer •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

07 Dec 2022 — GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code. GE CIMPICITY versiones 2022 y anteriores es vulnerable cuando los datos de una dirección defectuosa controlan el flujo de código a partir de gmmiObj!CGmmiOptionContainer, lo que podría permitir a un atacante ejecutar código arbitrario. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04 • CWE-824: Access of Uninitialized Pointer •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

07 Dec 2022 — GE CIMPICITY versions 2022 and prior is vulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code. Las versiones 2022 y anteriores de GE CIMPICITY son vulnerables a un desbordamiento de búfer de almacenamiento dinámico, lo que podría permitir a un atacante ejecutar código arbitrario. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04 • CWE-122: Heap-based Buffer Overflow •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

07 Dec 2022 — GE CIMPICITY versions 2022 and prior is vulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code. GE CIMPICITY versiones 2022 y anteriores es vulnerable cuando los datos de la dirección defectuosa controlan el flujo de código que comienza en gmmiObj!CGmmiOptionContainer, lo que podría permitir a un atacante ejecutar código arbitrario. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04 • CWE-822: Untrusted Pointer Dereference •

CVSS: 6.7EPSS: 0%CPEs: 1EXPL: 0

15 Apr 2020 — A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to G... • https://www.us-cert.gov/ics/advisories/icsa-20-098-02 • CWE-269: Improper Privilege Management •

CVSS: 9.1EPSS: 0%CPEs: 3EXPL: 0

07 Dec 2018 — XXE in GE Proficy Cimplicity GDS versions 9.0 R2, 9.5, 10.0 XEE (XML External Entity) en GE Proficy Cimplicity GDS en versiones 9.0 R2, 9.5 y 10.0. • http://www.securityfocus.com/bid/106133 • CWE-611: Improper Restriction of XML External Entity Reference •

CVSS: 6.7EPSS: 0%CPEs: 3EXPL: 0

13 Feb 2017 — An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session. Se encontró un problema en General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 y versiones anteriores, Proficy HMI/SCADA CIMPLICITY Versión 9.0 y versiones anteriores y P... • http://www.securityfocus.com/bid/95630 • CWE-522: Insufficiently Protected Credentials •