8 results (0.003 seconds)

CVSS: 9.9EPSS: 0%CPEs: 1EXPL: 0

The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application. • https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 9.9EPSS: 0%CPEs: 1EXPL: 0

A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential. • https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-943: Improper Neutralization of Special Elements in Data Query Logic •

CVSS: 8.8EPSS: 0%CPEs: 13EXPL: 0

An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. An authenticated user can launch an administrator level remote code execution irrespective of the authenticated user's role. Existe una vulnerabilidad de validación de entrada en la interfaz Monitor Pro de MicroSCADA Pro y MicroSCADA X SYS600. Un usuario autenticado puede iniciar una ejecución remota de código a nivel de administrador independientemente de la función del usuario autenticado. • https://search.abb.com/library/Download.aspx?DocumentID=8DBD000123&LanguageCode=en&DocumentPartId=&Action=Launch&elqaid=4293&elqat=1 • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 2EXPL: 0

Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* Una vulnerabilidad de comprobación de entrada inapropiada en el manejo de un paquete TCP IEC 104 malformado en Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Al recibir un paquete TCP IEC 104 malformado, el paquete malformado es descartado, pero la conexión TCP es dejada abierta. • https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 2EXPL: 0

Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* Una vulnerabilidad de comprobación de entrada inapropiada en Hitachi Energy MicroSCADA X SYS600 mientras es leído un archivo de configuración específico causa un desbordamiento del búfer que causa un fallo en el inicio del SYS600. Sólo puede accederse al archivo de configuración mediante un acceso de administrador. Este problema afecta a: Hitachi Energy MicroSCADA X SYS600 versión 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*:* • https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch https://publisher.hitachienergy.com/preview?DocumentId=8DBD000106&languageCode=en&Preview=true • CWE-20: Improper Input Validation CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •