5 results (0.003 seconds)

CVSS: 7.1EPSS: 0%CPEs: 21EXPL: 0

22 Nov 2022 — A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtai... • https://publisher.hitachienergy.com/preview?DocumentID=8DBD000120&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-312: Cleartext Storage of Sensitive Information •

CVSS: 2.8EPSS: 0%CPEs: 1EXPL: 0

10 Jun 2016 — ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file. ABB PCM600 en versiones anteriores a 2.7 utiliza un algoritmo hash inadecuado para la contraseña principal de la aplicación, lo que facilita a usuarios locales obtener información sensible en texto plano aprovechando acceso de lectura al archivo de configuración ACTConfig. • https://ics-cert.us-cert.gov/advisories/ICSA-16-152-02 • CWE-310: Cryptographic Issues •

CVSS: 3.3EPSS: 0%CPEs: 1EXPL: 0

10 Jun 2016 — ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors. ABB PCM600 en versiones anteriores a 2.7 no almacena correctamente la contraseña principal de la aplicación después de un cambio de contraseña, lo que permite a usuarios locales obtener información sensible a través de vectores no especificados. • https://ics-cert.us-cert.gov/advisories/ICSA-16-152-02 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 6.5EPSS: 0%CPEs: 1EXPL: 0

10 Jun 2016 — ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors. ABB PCM600 en versiones anteriores a 2.7 no almacena correctamente contraseñas OPC Server IEC61850 en circunstancias temporales no especificadas, lo que permite a usuarios locales obtener información sensible a través de vectores desconocidos. • https://ics-cert.us-cert.gov/advisories/ICSA-16-152-02 • CWE-284: Improper Access Control CWE-310: Cryptographic Issues •

CVSS: 3.3EPSS: 0%CPEs: 1EXPL: 0

10 Jun 2016 — ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors. ABB PCM600 en versiones anteriores a 2.7 no almacena correctamente credenciales de autenticación PCM600, lo que permite a usuarios locales obtener información sensible a través de vectores no especificados. • https://ics-cert.us-cert.gov/advisories/ICSA-16-152-02 • CWE-255: Credentials Management Errors •